Please be subject to the actual product purchased.The above indoor and outdoor units’ picture is just for your reference.Indoor/Outdoor Unit Installation DrawingsThe models adopt HFC refrigerant R32.For installation of the indoor units,refer to the installation manual which was provided with the units.(The diagram shows a wall-mounted indoor unit.)AIR OUTLETAIR INLETCONNECTING PIPING AND ELECTRICAL WIRINGDRAIN HOSE4Compressor(Inside of Unit)12If using the left side drain pipe, make sure the hole is got through.FCOptional parts for pipingNon-adhesive tapeAdhesive tapeSaddle (L.S) with screwsConnecting electric cablefor indoor and outdoorDrain hoseHeating insulating materialPiping hole coverFixing of outdoor unitFix the unit to concrete or blockwith bolts (10mm) and nuts rmlyand horizontally.When tting the unit to wallsurface, roof or rooftop, xa supporter surely with nailsor wires in consideration ofearthquake and strong wind.If vibration may affect thehouse, x the unit by attaching avibration-proof mat.The marks from toin the gure are theparts numbers.The distance betweenthe indoor unit and theoor should be morethan 2m.more than 10cmmore than 15 cmmore than 10cmmore than 20cmmore than 25cmmore than 60cmAGAFCEDGBArrangement of pipingdirectionsRear leftLeft RearrightRightBelowAttention must be paid tothe rising up of drain hoseIndoor unit AIndoor unit BEDmore than 20cm