Commercial Air Conditioner Model: AP*****EAA AU*****EAA2410. Electric data10.1 Electric Wiring diagram and PCB photoB:BLACK NOTE˖1ǃREMOTE CONTROLLER IS OPTIONAL .2ǃREFER TO OPERATION INDOOR MANUL TO SET DIP BM1-BM4 .PLEASE DO NOT CHANGE THE DIP SWITCH RANDOM.3ǃNO ELECTRIC HEATING TYPE WITHOUT ELECTRIC HEATER.R:REDBL:BLUEW:WHITEY/G:YELLOW/GREEN21 3CN13CN12CN11CN22 CN2SWING MOTORCONTROL PANELROOM TEMP. SENSORPIPING TEMP. SENSORSWING MOTORREMOTE CONTROLLERY/GY/GFAN MOTORHEATERTO OUTDOOR UNITWONE-OFF FUSERESUMABLE PROTECTORBRCAPACITORFUSEMMBYBLRT3.15A/250VACCN23CN3BM2BM1CN4CN24CN25CN10BM4BM3CN7CN5 CN6TRANSFORMERCIRCUIT DIAGRAM OF INDOOR UNITM0010578100AP482AKEAA