Service diagnosis42 Domestic air conditioner10.3.11 Loss of synchronism detectionInverter side current detection is abnormalOutdoor Display LED1 flash 18 timesLED1 flash 19 timesMethod of The position of the compressor rotor can not detected normallyMalfunctionDetectionMalfunction when the wiring of compressor is wrong or the connection is poor;Decision or the compressor is damagedConditionsSupposed Faulty The wiring of compressorCauses Faulty compressorFaulty PCBTroubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or partsdamage may be occurred.Within 3 minutes after the machine issupplied with power and turned on withthe remote controller, check whetherthe compressor can start up1. The wiring of compressor is incorrector the connection is poor;2. The compressor is damagedAt first, the compressor start up ,soon thecompressor stopped with the LED1 on theoutdoor PCB blinks 1Hz 19/18 times IPM Module is damaged and needsreplacing.the Malfunctions exist also, thecompressor is damaged replace anew oneYESNOYESMalfunction unsolvedMaybe there is some disturbance