24Installation Manual of Room Air Conditionerselection of installation placePlace where it is easy to route drainage pipeand outdoor piping.Place ,away from heat source and with lessdirect sunlight.Place where cool and warm air could bedelivered evently to every corner of the room.Place near power supply socket.Leave enoughspace around the unit.Place ,robust not causing vibration,where thebody can be supported sufficiently.ToInstallationAccording to the dimension of the Figure 2 shownnail two cement steel nails on the wall.keep 2~3mmout .then hang the back of the unit on them.There must be no gap between the indoor unit andwall.Remove the front panel,then use two fasteningscrews to fix the unit on the floor.As Figure 3 shown.Once refrigerant piping and drain piping connectionsare complete,fill the gap of the through hole with putty.Attach the front panel and front grille in their orginalpositions once all connections are complete.prevent interference, place it at least 1maway from other electric machines, such asTV set, radio.Installation of indoor unitInstallation of outdoor unitselection of installation placePlace strong enough to support the unit and willnot cause vibration and noise.Place where discharged wind and noise doesntcause a nuisance to the neighbors.Place where is less affected by rain or direct sunlightand is sufficiently ventilated,or to install a shield.Place with enough space for smooth air flow.more than 10cm330617Figure .1Figure .2Figure .3more than 10 cmmore than 10 cmmore than 10 cmmore than 10 cmmore than 10 cmmore than 60 cmmore than 100 cmFigure .4