PERFORMANCE CURVESIndoor temp.D.B. / W.B. 18ć 20ć 25ć 32ć 35ć/24ć 40ć 43ć 46ć18/14ć 11.6 11.4 10.9 10.4 9.8 9.3 8.8 8.420/15ć 12.0 11.7 11.4 10.9 10.2 9.8 9.3 8.822/16ć 12.4 12.1 11.7 11.5 11.0 10.1 9.8 9.325/18ć 13.3 12.9 12.7 12.3 11.8 11.0 10.7 10.227/19ć 13.8 13.4 13.2 12.9 12.5 11.4 11.1 10.730/22ć 15.4 15.0 14.5 14.1 13.6 12.7 12.3 11.832/23ć 16.0 15.5 15.1 14.5 14.0 13.3 12.8 12.2Indoor temp.D.B. / W.B. 18ć 20ć 25ć 32ć 35ć/24ć 40ć 43ć 46ć18/14ć 4.0 4.1 4.2 4.5 4.7 5.1 5.3 5.520/15ć 4.0 4.1 4.2 4.6 4.7. 5.1 5.4 5.622/16ć 4.1 4.2 4.2 4.6 4.8 5.2 5.4 5.725/18ć 4.1 4.3 4.3 4.7 4.9 5.3 5.6 5.827/19ć 4.2 4.4 4.4 4.8 5.0 5.4 5.6 5.930/22ć 4.4 4.5 4.6 5.0 5.2 5.6 5.8 6.132/23ć 4.5 4.6 4.6 5.0 5.2 5.7 5.9 6.2Outdoor temp.Power consumption chart (kW) (change with the temperature)AU422XIBAAOutdoor temp.AU422XIBAACooling capacity chart (kW) (change with the temperature)The data is measured in the normal condition: outdoor DB/WB 35/24, indoor DB/WB 27/19High drop and long pipe: capacity modification curvesAU422XIBAA1512.5107.552.50-2.5-5-7.5-100 5 7.5 10 12.5 15 17.5 20100% 88%98% 96% 94% 92% 90%Equivalent total distance between indoor and outdoor unit of one way (m).The standard installation piping length and drop should within this range.Drop between the indoor and outdoor unit(m).H>0: Outdoor unit higher than indoor unit