Drawing for the installation of indoor and outdoor unitsNecessary Tools for InstallationDriverƽ Torque wrenchƽ(17mm,22mm,26mm)NipperƽReamerƽHacksawƽ Pipe cutterƽGas leakage detector orƽsoap-and-water solutionHole core drillƽ Flaring toolƽSpanner(17,19 and 26mm)ƽ KnifeƽMeasuring tapeƽIndoor UnitPlace, robust not causing vibration, where the body can be supported sufficiently.ƽ Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of theunit are not disturbed.ƽPlace, possible to drain easily, where piping can be connected with the outdoor unit.ƽPlace, where cold air can be spread in a room entirely.ƽ Place, nearby a power receptacle, with enough space around. (Refer to drawings).ƽPlace where the distance of more than lm from televisions, radios, wireless apparatusesand fluorescent lamps can be left.ƽIn the case of fixing the remote controller on a wall, place where the indoor unit canreceive signals when the fluorescentƽ lamps in the room are lightened.Outdoor UnitPlace, which is less affected by rain or direct sunlight and is sufficiently ventilated.ƽPlace, possible to bear the unit, where vibration and noise are not increased.ƽPlace, where discharged wind and noise do not cause a nuisance to the neighbors.ƽPlace, where a distance markedƽ is available as illustrated in the above figure.Before inserting power plug into receptacle, check the voltage without fail.The power source is the same as theƽ corresponding name plate.Install an exclusive branch circuit of the power.ƽA receptacle shall be set up in a distance where the power cable can bereached.Do not extend the cable by cutting it.ƽPower SourcePreparationRead this manual before installationExplain sufficiently the operating means to the user according to this manual.NO.0010531114Installation Manual of Room Air ConditionerFACEOptional parts for pipingNon-adhesive tapeAdhesive tapeSaddle (L.S) with screwsConnecting electric cablefor indoor and outdoorDrain hoseHeating insulating materialPiping hole coverFloor fixing dimensions of theoutdoor unit (Unit:mm)Fixing of outdoor unitFix the unit to concrete or blockƽwith bolts (10mm) and nuts firmlyand horizontally.When fitting the unit to wallƽsurface, roof or rooftop, fixa supporter surely with nailsor wires in consideration ofearthquake and strong wind.If vibration may affect theƽhouse, fix the unit by attaching avibration-proof mat.The marks from toin the figure are theparts numbers.The distance betweenthe indoor unit and thefloor should be morethan 2m.The models adopt HFC free refrigerant R410Amore than 10cmmore than 5cmmore than 10cmmore than 10cmmore than10cmmore than15cmmore than60cmAGƽƽAFCEDGBArrangement of pipingdirectionsRear leftLeft RearrightRightBelowGPlease be subject to the actual product purchased , the above picture is just for your reference.Attention must be paid tothe rising up of drain hose113.5 583 113.55.913Selection of Installation PlaceUnit AUnit BTo unit ATo unit B