1-2-6. Safety Check after RepairmentConfirm that the screws ,parts and wiring which were removed in order to service are put in theoriginal positions, or whether there are the portions which are deteriorated around the servicedplaces serviced or not. Check the insulation between the antenna terminal or external metal andthe AC cord plug blades. And be sure the safety of that.Insuration Test1. Unplug the plug from the AC outlet.2. Remove the antenna terminal on TV and turn on the TV.3. Insulation resistance between the cord plug terminals and the eternal exposure metalshould be more than M ohm by using the 500V insulation resistance meter4. If the insulation resistance is less than M ohm, the inspection repair should be required.If you have not the 500V insulation resistance meter, use a Tester.External exposure metal: Antenna terminal Headphone jack1-2-7. Ordering Spare PartsPlease include the following informations when you order parts. (Particularly the Versionletter)1. Model number and Version letterThe model number can be found on the back of each product and the Version letter canbe found at the end of the serial number.2. Part No. and DescriptionYou can find them in your service manual.1-2-8. Photo used in this manualThe illustration and photos used in this Manual may not base on the final design of products, whichmay differ from your products in some way.1-3. How to read this Service Manual1-4-1. Using IconsIcons are used to attract the attention of the reader to specific information. The meaning of each icon isdescribed in the table below:Note:A “note” provides information that is not indispensable, but may nevertheless be valuable to thereader, such as tips and tricks.Caution:A “caution” is used when there is danger that the reader, through incorrect manipulation,