OperationSleep OperationIf the wind speed is high or middle before setting for thesleep, set for lowing the wind speed after sleeping.If it is low wind, no change.5.Set the wind speed change when sleepingUse of SLEEP functionOperation Mode1. In COOL,DRY modeSLEEP operation starts SLEEP operation stopsSLEEPoperation startsSLEEPoperation stopsApprox.6hrs1 hr1 hr1 hr3 hrs3 hrsRises 1 OCRises 1OCRises 1 OCTemp.settingTemp.settingUnit stopUnit stopIn COOL, DRY modeIn HEAT modeDecreases 2O CDecreases 2O C1 hr2.3.In HEAT modeIn AUTO mode4. In FAN modeIt has no SLEEP function.NoteWhen TIMER function is set, the sleeping function can’t beset up .After the sleeping function is set up ,TIMER function, the sleeping function will be cancelled; themachine will be in the state of timing-on.POWER/SOFT OperationHEALTHY OperationHealthy Negative ionsBefore going to bed,you can simply press the SLEEPbutton and unit will operate in SLEEP mode and bringyou a sound sleep.After the unit starts,set the operation status,then pressSLEEP button before which the clock must be adjudtedand time being set.1 hours after SLEEP mode starts,temp.will becomehigher than temp.setting.After another 1 hours,temp.risesby 1 futher.The unit will run for further 6 hours then stopsTemp. is higher than temp.setting so that room temperaturewon’t be too low for your sleep.1 hours after SLEEP mode starts,temp will become 2lower than temp.setting.After another 1 hours,tempdecrease by 2rises by 1 futher.The unit will run for further 3 hours thenstops.Temp.is lower than temp. setting so that roomtemperature won’t be too high for your sleep.The unit operaters in corresponding sleep modeadapted to the automatically selected operation mode.The anion generator in the airconditioner can generate a lotof anion effectively balance the quantity of position and anionin the air and also to kill bacteria and speed up the dustthe room and finally clean the air in the room.O COC futher.After more another 3 hours,temp.O C4(1) POWER Operation(2) SOFT OperationPress POWER/SOFT button again ,POWER or SOFTdisappears.To cancel POWER or SOFT operationNote ˖When you need rapid heating or cooling, you can use thisfunction. In COOL mode, fan speed automatically takeshigh speed of AUTO fan mode. In HEAT mode, fan speedautomatically takes medial speed of AUTO fan mode.You can use this function when silence is needed for rest or reading.In SOFT operation mode, fan speed automatically takes low speedof AUTO fan mode.During POWER operation, in rapid HEAT or COOLmode , the room will show inhomogeneous temperaturedistribution. Long period SOFT operation will causeeffect of not too cool or not too warm.1 OCO Cif user resetssediment inUV light emitted by the UV light device of the indoor unitcatalytically activates the nano TiO 2 on the multi-lightstouching intermediary, and the degerming effect is highlyNote: when the function is running, don't open the inlet grille.About UV light degerming functionefficient and lasting.