3OperationAir Flow Direction AdjustmentAUTO COOL DRY FANHEAT2.Select operation modePress FAN button. For each press, fan speedfollows:Press MODE button. For each press, operation modechanges as follows:Remote controller:Remote controller:Press buttonEvery time the button is pressed, temp.settingincrease 1 oC,if kept depressed, it will increaserapidlyEvery time the button is pressed, temp.settingdecrease 1 oC,if kept depressed, it willdecrease rapidlySelect a desired temperature.4.Fan speed selection3.Select temp.settingAir conditioner is running under displayed fan speed.When FAN is set to AUTO, the air conditionerautomatically adjusts the fan speed according to roomtemperature.1. Unit startPress ON/OFF on the remote controller, unit starts.Base OperationRemote controllerVertical flapPos.1 blank Pos.2 Pos.3Pos.4 (Auto swing)1.Status display of air flowWhen restart after remote turning off, the remotememorize the previousMove the vertical blade by a knob on airto adjust left and right direction referring to Fig.2.Left and right air flow adjustment(manual)Cautions:When adjusting the flap by hand,turn off the unit.When humidity is high,condensate water might occuradjusted to left orIt is advisable not to keep horizontal flap at downwardposition for a long time in COOLor DRYotherwise, condensate water might occur.conditionerEmergency operation and test operationat air outlet if all vertical louvers areright.mode ,controller will automaticallyNote:set swing position.changes as'OperationModeAUTORemoteController NoteCOOLDRYHEATFANIn DRY mode , when room temperature becomeslower than temp.setting+2 o C, unit will runintermittently at LOW speed regardless of FANUnder the mode of auto operation, air conditionerwill automatically select Cool or Heat operationaccording to room temperatureto AUTO the air conditioner automatically adjuststemperature.When FAN is setthe fan speed according to roomIn FAN operation mode , the unit will not operate inCOOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode. And temp.setting is disabled. In FAN mode, sleep operationsetting.is not available.AUTO LO MED HION/OFFFANMODELOCK RESET SWINGTIMERCLOCKSET SLEEPPOWER/SOFTLIGHTtest operationswitchPi PiEmergency Operation:Use this operation only when the remote controller is defectiveor lost, and with function of emergency running, air conditonercan run automatically for a while.When the emergency operation switch is pressed, the " Pi "sound is heard once, which means the start of this operation.When power switch is turning on for the first time andemergency operation starts, the unit will run automatically inthe following modes:Roomtemperature DesignatedtemperatureTimermode Fanspeed OperationmodeAbove 23 oCBelow 23o C 23o C26o CNoAUTOAUTOCOOLHEATNoPiemergencyoperation switchIt is impossible to change the settings of temp. and fan speed,Itis also not possible to operate in timer or dry mode.temperature is below 16 oC, do not use it in theTest operation:Use this switch in the test operation when the roomnormal operation.your finger from the switch: the coolingContinue to press the test operationswitch for more than 5 seconds . Afteryou hear the "Pi" sound twice, releaseTest ope ration switch is the same as emergency switch.operation starts with the air flow speed "Hi".Under this operation mode,the fan motor of indoorunit will run in high speed.In HEAT mode, warm air will blow out after a shortperiod of the time due to cold-draft prevention function.When FAN is set to AUTO, the air conditioner automaticallyadjusts the fan speed according to room temperature.