20Trouble shootingBefore asking for service, check the following first.NormalPerformanceinspectionNoise is heardPhenomenon Cause or check pointsThe system does not restartimmediately.Smells are generated.Mist or steam are blown out.MultiplecheckPoor coolingApplication temp. range of air conditioner -7oC~43oC.When unit is stopped, it won't restartimmediately until 3 minutes have elapsedto protect the system.When the electric plug is pulled out andreinserted, the protection circuit will workfor 3 minutes to protect the air conditioner.During unit operation or at stop, a swishingor gurgling noise may be heard. At first 2-3minutes after unit start, this noise is morenoticeable. (This noise is generated byrefrigerant flowing in the system.)During unit operation, a cracking noise maybe heard. This noise is generated by thecasing expanding or shrinking because oftemperature changesShould there be a big noise from air flow inunit operation, air filter may be too dirty.This is because the system circulates smellsfrom the interior air such as the smell offurniture, paint, cigarettes.During COOL or DRY operation, indoor unitmay blow out mist. This is due to the suddencooling of indoor air.Is power plug inserted?Is there a power failure?Is fuse blownout?Is the air filter dirty? Normally it should becleaned every 15 days.Are there any obstacles before inlet and outlet?Is temperature set correctly?Are there some doors or windows left open?Is there any direct sunlight through thecurtain)window during the cooling operation?(UseAre there too much heat sources or too manypeople in the room during cooling operation?In dry mode, fanspeed can’t be changed.In DRY mode, when room temperature becom-es lower than temp.setting+2o C,unit will runintermittently at LOW speed regardless of FANsetting.