Indoor unit3.Installation of the Indoor UnitDrawing of pipeRear pipingLeft Left-rear pipingDraw pipes and the drain hose, then fasten them with the adhesive tapeIn case of left side piping, cut away, with a nipper, the lid for left piping.In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rearpiping which is marked on heat insulation materials.1. Insert the drain hose into the dent of heat insulation materials of indoor unit.2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, thenconnect them.3. Coat the flaring seal face with refrigerant oil and connect pipes.Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tapeOther direction pipingIndoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe accordingto the position of wall hole. When bending, be careful not to crash pipes.Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulationof connecting part specially.Lid for right pipingLid for under piping pipeLid for left pipingHeat insulationmaterialDrain hosePipingIndoor/outdoorelectric cableFix with adhesive tapePipe supporting plateFixing the indoor unit bodyHang surely the unit body onto the upper notches of themounting plate. Move the body from side to side to verifyits secure fixing.In order to fix the body onto the mounting plate,hold upthe body aslant from the underside and then put it downperpendicularly.44.Connecting the indoor/outdoor Electric CableRemoving the wiring coverRemove terminal cover at right bottom corner of indoor unit, thentake off wiring cover by removing its screws.