Drawing for the installation of indoor and outdoor unitsNecessary Tools for InstallationHammerƽ Torque wrenchƽ(17mm,22mm,26mm)NipperƽReamerƽHacksawƽ Pipe cutterƽGas leakage detector orƽsoap-and-water solutionHole core drillƽ Flaring toolƽSpanner(17,19 and 26mm)ƽ KnifeƽMeasuring tapeƽƽƽƽƽƽPlace where the distance of more than lm from televisions, radios, wireless apparatusesand fluorescent lamps can be left.ƽIn the case of fixing the remote controller on a wall, place where the indoor unit canreceive signals when the fluorescentƽ lamps in the room are in use.ƽƽPlace, where discharged wind and noise do not cause a nuisance to the neighbors.ƽPlace, where a distance markedƽ is available as illustrated in the above figure.Before inserting power plug into receptacle, check the voltage without fail.The power source is the same as theƽ corresponding name plate.Install an exclusive branch circuit of the power.ƽA receptacle shall be set up in a distance where the power cable can bereached.Do not extend the cable by cutting it.ƽSelection of Installation PlacePower SourcePreparationNO.0010536243Installation Manual of Room Air ConditionerThe models adopt HC FC free refrigerant R410AIndoor Unit - Select a plocation that isOutdoor Unit - Select a plocation that isRobust not causing vibration, where the body can be supported sufficiently.Not affected by heat or steam generated in the vicinity, where inlet and outlet of theunit are not disturbed.Possible to drain easily, where piping can be connected with the outdoor unit.Where cold air can be spread in a room evenly.Nearby a power receptacle. (Refer to drawings).Not less affected by rain or direct sunlight and is sufficiently ventilated.Strong enough to bear the unit, where vibration and noise are not increased.Please be subject to the actual product purchased , the above picture is just for your reference.Read this manual before installationExplain suf ciently the operating means to the user according to this manual.Optional parts for pipingNon-adhesive tapeAdhesive tapeSaddle (L.S) with screwsConnecting electric cablefor indoor and outdoorDrain hoseHeating insulating materialPiping hole coverFloor xing dimensions of theoutdoor unit (Unit:mm / inch)Fixing of outdoor unitFix the unit to concrete or blockwith bolts (10mm) and nuts rmlyand horizontally.When tting the unit to wallsurface, roof or rooftop, xa supporter surely with nailsor wires in consideration ofearthquake and strong wind.If vibration may affect thehouse, x the unit by attaching avibration-proof mat.The marks from toin the gure are theparts numbers.The distance betweenthe indoor unit and theoor should be morethan 2m.more than 10cmmore than 10cmmore than 10cmmore than 20cmmore than 15cmmore than 25cmmore than 60cmAGAFCEDGBArrangement of pipingdirectionsRear leftLeft RearrightRightBelowAttention must be paid tothe pitch of drain hoseAC184 580 184083For:HSU24VCK-W(3 7/8)(3 7/8)(3 7/8)(7 7/8)(23 5/8) (9 7/8)(5 7/8)(4 1/2)For:HSU18VCK-W(24 7/8) (4 1/2)(13 1/2)113.5 113.5633340(14 15/16)(7 1/4)(22 7/8)(7 1/4)