13STATIC CONVERGENCE ADJUSTMENT1. Input a crosshatch signal.2. Using 4-pole convergence magnets overlap the redand blue lines in the center of the screen (Fig. 1) andturn them to magenta (red/blue).3. Using 6-pole convergence magnets overlap themagenta (red/blue) and green lines in the center of thescreen and turn them to white.4. Repeat 2 and 3 above, and make the bestconvergence.DYNAMIC CONVERGENCE ADJUSTMENT1. Move the deflection yoke up and down and overlaplines in the periphery. (Fig. 2)2. Move the deflection yoke left to right and overlap thelines in the periphery. (Fig. 3)3. Repeat 1 and 2 above, and make the bestconvergence.After adjustment, fix the wedge at the original position.Fasten the retainer screw of the deflection yoke.Fix the 6 magnets with glue.9 CIRCUIT DIAGRAM(FRONT VIEW)Fig. 1(FRONT VIEW)RED GREEN BLUEBLUEREDGREEN GREENRED BLUEBLUE GREEN REDFig.2(FRONT VIEW)RED GREEN BLUE BLUE GREEN REDREDGREENBLUEBLUEGREENREDFig. 3