34Smart Power2. SpecificationItem Model ADH071M1ERG/1UH071N1ERGFunction Cooling HeatingCapacity kW 7.1 (2.0~9.0) 8 (2.0~10.0)0.72 /kW 2.03 (0.4~4.0) 2.0 (0.4~4.0)W 4000 4000W/W 3.41 3.8910 -3 ×m3/hN, V, HzH05RN-F 4G 2.5mm24.0mm21, 220-240, 50/60A/A 8.8 (2.0-17.5) /17.5 9.2 (2.0-17.5) /17.5A 3Sensible heat ratioTotal power inputMax. power inputAEER or ACOP Dehumidifying capacityConnection cable( from outdoor to indoor)Power sourceRunning/Max.Running current Start currentCircuit breakerA 1ph,30A (from outdoor)IndoorunitUnit model (color) ADH071M1ERGFanType×Number CENTRIFUGALX2Speed (H-M-L) r/min 950/860/760Fan motor output/ input power W 85/111Air-flow (H-M-L) m 3/h 1050/840/630External static pressure Pa 10/30(default)/50/70HeatexchangerType / Diameter mm Inner grooved pipe/φ7.0Row 3Total area m2 7.668Dimension External (L×W×H) mm×mm×mm 957/655/250Package (L×W×H) mm×mm×mm 1170/860/340Drainage pipe (material, I.D./O.D.) mm PVC 25/29Controller (O-Optional, S-Standard) Wired YR-E16A(O)/YR-E17(S)Infrared YR-HBS01(O)Fresh air hole dimension mm 145Electricity heater kW /Sound power noise level (H) dB (A) 58Sound pressure noise level (H-M-L) dB (A) 38/35/32Weight (Net/Shipping) kg / kg 31.2/36.8PipingRefrigerant Type / Charge g R410A/2500Recharge quantity g/m 45PipeLiquid m 9.52Gas mm 15.88Max.pipe lengh withoutcharge refrigerant mm 20BetweenI.D &O.DMAX.Drop m 30MAX.Piping length m 50Connecting method FlaredCooling Pdesignc (kW): 7.1kW SEER/CLASS 6.3/A++ QCE(Annual electricityconsumption for cooling)kWh: 390HeatingAverage Pdesignh (-10°C) 6.0kW SCOP/CLASS 4.2/A+ QHE(Annual electricityconsumption for heating)kWh:1982Warmer Pdesignh (2°C) 6.0kW SCOP/CLASS 4.8/A++ 1652Colder Pdesignh (-22°C) / SCOP/CLASS / /Tdesignh: -10°C Tbivalent: -10°C TOL: -15°C Elbu: 0Max. coolingconditionIndoor temperature: 32°C/23°C Max. heating condition Indoor temperature: 27°C/-°COutdoor temperature: 46°C/-°C Outdoor temperature: 24C/18CNorminal condition:Indoor temperature (cooling) : 27DB (°C)/19WB (°C) , Indoor temperature (heating) : 20DB (°C)Outdoor temperature (cooling) : 35DB (°C)/24WB (°C) , Outdoor temperature (heating) : 7DB (°C)/6WB (°C)The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensitymeter. It is a sound pressure noise level.