Appendix AA-6ASCII Input ShortcutTo configure the user definable parameters of the scanner viathe programming bar codes, you will be asked to scan yourdesired ASCII value in HEX form. You have to refer to the“HEX/ASCII Table” for details.Example:If you want the scanned data output leading with a Dollar Sign,you have to set the “Preamble” to “$.” The configurationprocedure is listed below for reference. Scan the system command – PROGRAM listed on page3-22 to enter programming mode. Scan family code – PREAMBLE to select this family. In the Hex/ASCII Table, you will find the HEX value of“$” is 24. Scan the option code – 2 listed on the foldout back cover. Scan the option code – 4 listed on the foldout back cover. Scan the system command – FIN (Finish) to terminatePreamble setting. Scan the system command – End to exit the programmingmode for normal operation.HEX/ASCII Reference Table0 1 2 3 4 5 6 70 NUL DLE SPACE 0 @ P ` p1 SOH DC1 ! 1 A Q a q2 STX DC2 " 2 B R b r3 ETX DC3 # 3 C S c s4 EOT DC4 $ 4 D T d t5 ENQ NAK % 5 E U e u6 ACK SYN & 6 F V f v7 BEL ETB ' 7 G W g w8 BS CAN ( 8 H X h x9 HT EM ) 9 I Y i yA LF SUB * : J Z j zB VT ESC + ; K [ k {C FF FS , < L \ l |D CR GS - = M ] m }E SO RS . > N ^ n ~F SI US / ? O _ o DELExample : ASCII “A” → HEX “41;” ASCII “a” → “61”: High Byte of HEX Value: Low Byte of HEX Value