4EnglishAssembly (see page 31)Safety NotesGloves should be worn during installation to preventcrushing and cutting injuries.The hot and cold supplies must be of equalpressures.Installation Instructions• Prior to installation, inspect the product for transportdamages. After it has been installed, no transport orsurface damage will be honoured.• The pipes and the fixture must be installed, flushedand tested as per the applicable standards.• The plumbing codes applicable in the respectivecountries must be observed.• The fittings must be mounted in an insulated mannerand with sound insulation.Assembly (see page 31)• Install body with Rp 3/4 outlet pointing downwards.• Depth of fitting: 68 mm to 96 mm.• extension set 28 mmNote: When installation is complete ensurethat the mixer is turned off!A Direct wall installation.B Direct wall installation with 10 mm adjustablemounting studs.C Brick wall installation.Technical DataThis mixer series-produced with EcoSmart®(flow limiter)Operating pressure: max. 1 MPaRecommended operating pressure: 0,1 - 0,5 MPaTest pressure: 1,6 MPa(1 MPa = 10 bar = 147 PSI)Hot water temperature: max. 70°CRecommended hot water temp.: 65°CConnections Rp 1/2: cold right - hot leftThe product is exclusively designed for drinking water!Symbol descriptionDo not use silicone containing acetic acid!Adjustment (see page 32)To adjust the hot water limiter. Using a hot water limiterin combination with a continuous flow water heater isnot recommended.Dimensions (see page 33)Flow diagram (see page 33) Tub outlet Shower outletSpare parts (see page 34)Special accessories (order as anextra)• extension set 28 mm #32498000(see page 34)Final assembly (see page 35)