4EnglishAssembly (see page 33)Safety NotesGloves should be worn during installation to prevent crushing and cuttinginjuries.The product may only be used for bathing, hygienic and body cleaningpurposes.Children as well as adults with physical, mental and/or sensoric impairmentsmust not use this product without proper supervision. Persons under the influenceof alcohol or drugs are prohibited from using this product.The hot and cold supplies must be of equal pressures.Installation Instructions• Prior to installation, inspect the product for transport damages. After it has beeninstalled, no transport or surface damage will be honoured.• The pipes and the fixture must be installed, flushed and tested as per theapplicable standards.• The plumbing codes applicable in the respective countries must be observed.• The product is not designed to be used with steam baths!• If the continuous water heater causes any problems, or you have different waterpressures you must install a water limiter to the cold supply, (ordered separate-ly,article number 97510000).Technical DataOperating pressure: max. 1 MPaRecommended operating pressure: 0,1 - 0,5 MPaTest pressure: 1,6 MPa(1 MPa = 10 bar = 147 PSI)Hot water temperature: max. 60°CCentre distance: 150±12 mmConnections G 1/2: cold right - hot leftThermal disinfection: 70°C / 4 min• Safety against backflow• The product is exclusively designed for drinking water!Symbol descriptionDo not use silicone containing acetic acid!Safety Function (see page 34)The desired maximum temperature for example max. 42º C can be pre-set thanks tothe safety function.Adjustment (see page 34)After the installation, the output temperature of the thermostat must be checked. Acorrection is necessary if the temperature measured at the output differs from thetemperature set on the thermostat.Maintenance (see page 40)• The check valves must be checked regularly according to EN 806-5 in accord-ance with national or regional regulations (at least once a year).• To guarantee the smooth running of the thermostat, it is necessary from time totime to turn the thermostat from total hot to total cold.Dimensions (see page 36)Flow diagram (see page 36) Shower outlet Tub outletSpare parts (see page 37)Cleaning (see page 36)Operation (see page 35)Test certificate (see page 37)Special information for UK (see page 38)iFault Cause RemedyInsufficient water - Supply pressure inadequate - Check water pressure (If a pump has been installedcheck to see if the pump is working).- Regulator filter dirty - Clean filter in front of the mixer and on the MTC-ther-mo cartridge- Shower filter seal dirty - Clean filter seal between shower and hoseCrossflow, hot water being forced into cold water pipe,or vice versa, when mixer is closed- Backflow preventers dirty or leaking - Clean backflow preventers, exchange if necessarySpout temperature does not correspond with tempera-ture set- Thermostat has not been adjusted - Adjust thermostat- Hot water temperature too low - Increase hot water temperature to 42 ºC to 60 ºCTemperature regulation not possible - thermo cartridge calcified - Exchange thermo cartridgeInstantaneous heater didn't work with thermostat - Filters are dirty - Clean the filter / exchange filter- check valve hasn't moved back - Exchange check valves- Flow limiter in handshower isn’t removed - Remove flow limiter- Ecostop limit stop washer not turned axially through180°- When mounting the ECOSTOP limit stop washer (Art.No. 98916000) in connection with flow heaters, turnit axially through 180° before attaching it.Shower or spout dripping - Dirt or sedimentation on valve seat, shut-off unitdamaged- Clean or exchange shut-off unit