EnglishSafety NotesGloves should be worn during installation to preventcrushing and cutting injuries.The shower system may only be used for bathing,hygienic and body cleansing purposes.The hot and cold supplies must be of equal pres-sures.Installation Instructions• Prior to installation, inspect the product for transportdamages. After it has been installed, no transport orsurface damage will be honoured.• The fitting must be installed, flushed and tested afterthe valid norms!• The plumbing codes applicable in the respectivecountries must be oberserved.• There must be an access door for maintenance.Thepremounted filter insert must be used to ensure anormal flow of the shower and to prevent dirt fromentering through the pipes. Dirt entering can affect thefunction and/or lead to damages to the shower. Hans-grohe will not be held liable for this type of damage.• The mesh washer must be insert to protect the over-head shower against incoming dirt by pipework. In-coming dirt leads to defects or/and can damage partsof the shower; such caused faults voids all liability andguarantee claims.Symbol descriptionDo not use silicone containing acetic acid!Adjustment (see page 12)To adjust the hot water limiter on single levermixers, please see page 12. Using a hotwater limiter in connection with a continuousflow water heater is not recommended.Maintenance (see page 16)The check valves must be checked regularlyaccording to DIN EN 1717 in accordancewith national or regional regulations (at leastonce a year).Cleaning (see enclosed brochure)Dimensions (see page 8)Flow diagram(see page 11)Spare parts (see page 14)Operation (see page 13)Technical DataOperating pressure: max. 1 MPaRecommended operating pressure: 0,05 - 0,5 MPaTest pressure: 1,6 MPaHot water temperature: max. 70°CRecommended hot water temp.: 65°CThermal disinfection: max. 70°C / 4 minTest certificate 31523000,31427000, 31423000: WRASHansgrohe mixers can be used together with hydrauli-cally and thermically controlled continuous flow heatersif the flow pressure is at least 0,15 MPa.The product is exclusively designed for drinking water!4