Assembly see page 31Fault Cause RemedyInsufficient water - Shower filter seal dirty - Clean filter seal between shower andhose- check valve hasn't moved back - Exchange check valvesMixer stiff - Cartridge defective, calcified - Exchange cartridgeMixer dripping - Cartridge defective - Exchange cartridgeHot water temperature too low - Hot water limiter incorrectly set - Set hot water limiterInstantaneous heater didn’t work - Flow limiter in handshower isn’t re-moved- Remove flow limiter- Filters are dirty - Clean the filter / exchange filter- check valve hasn't moved back - Exchange check valvesSpare parts (see page 38)Cleaningsee enclosed brochure.Test certificate (see page 40)Flow diagram(see page 36)Dimensions (see page 36)Operation (see page 35)Maintenance (see page 40)The check valves must be checked regularlyaccording to DIN EN 1717 in accordancewith national or regional regulations (at leastonce a year).Adjustment (see page 34)To adjust the hot water limiter on single levermixers, please see page 34. Using a hotwater limiter in connection with a continuousflow water heater is not recommended.Do not use silicone containing acetic acid!Symbol descriptionSafety NotesGloves should be worn during installation to preventcrushing and cutting injuries.The shower system may only be used for bathing,hygienic and body cleansing purposes.The hot and cold supplies must be of equal pres-sures.Installation Instructions• Prior to installation, inspect the product for transportdamages. After it has been installed, no transport orsurface damage will be honoured.• The fitting must be installed, flushed and tested afterthe valid norms!• The plumbing codes applicable in the respectivecountries must be oberserved.Technical DataOperating pressure: max. 1 MPaRecommended operating pressure: 0,1 - 0,5 MPaTest pressure: 1,6 MPa(1 MPa = 10 bar = 147 PSI)Hot water temperature: max.85°CRecommended hot water temp.: 65°CConnections: cold right - hot leftThermal disinfection: max. 70°C / 4 minSafety against backflowHansgrohe mixers can be used together with hydrauli-cally and thermically controlled continuous flow heatersif the flow pressure is at least 0,15 MPa.The product is exclusively designed for drinking water!English4