27HARDI MEGA 230 / 350 CENTRIFUGAL OPERATORS MANUAL5.4 Hydraulic Requirements with Eagle BoomHydraulic booms need one single outlet for the lift function of the sprayboom and one double outlet for the folding function. Note that thehydraulic system requires an oil capacity of approximately .8 GPM (3litres/min.)and a minimum pressure of 1,950 PSI (130 bar).5.5 Hydraulic Hook-upBE SURE TO HOOK UP HYDRAULIC LINES PROPERLY!ENSURE HYDRAULIC LINES HAVE NOT BEEN DAMAGED DURINGSHIPPING.ESCAPING HYDRAULIC FLUID UNDER PRESSURE CANPENETRATE THE SKIN CAUSING SERIOUS INJURY. AVOID THISHAZARD BY RELIEVING PRESSURE BEFORE DICONNECTINGHYDRAULIC LINES.ENSURE ALL CONNECTIONS ARE TIGHT BEFORE APPLYINGPRESSURE, SEARCH FOR LEAKS WITH A PIECE OF CARDBOARDNOT YOUR HANDS!IMPROPER HOOK-UP CAN CAUSE DANGEROUS BOOMMOVEMENTS AND/OR DAMAGE TO THE SPRAYER HYDRAULICS.DO NOT ALLOW ANYONE NEAR A HYDRAULIC BOOM INOPERATION.ALWAYS SHUT TRACTOR OFF WHEN CONNECTING, SERVICINGOR ADJUSTING BOOM.1. Attach the heavier (3/8") hydraulic hose for the boom lift to the tractor'ssingle acting outlet.2. Attach the lighter (1/4") hydraulic hoses for boom folding & HZ tilt tothe tractor's double acting outlet.