The Accentra Pellet Stove is capable of manual operation. This also allows the operator tomanually control operation during an emergency (i.e. igniter failure, when using a 502H batterybackup, or when using certain generators.)The unit can be switched between "AUTO" and "MANUAL" at any time during operation.Ignitor Switch to "MANUAL"Room Temperature ModeThe fire will have to be lit with starting gel and a match,or started automatically, see "Automatic Operation". Turnto "Manual" position when the fire is established.The difference between "AUTO" Room TemperatureMode and "Manual" Room Temperature Mode is that thefire will not go out as the room temperature goes above thecontrol board setting. The unit can only go to low burn andwill remain there until it runs out of fuel or until more heat isneeded and the feed rate increases. Feed rate adjustmentsand dial settings are the same as "AUTO" settings.Ignitor Switch to "MANUAL"Stove Temperature ModeThe advantage of this mode is to allow the operator tohave a large viewing fire without blowing extra heat into theroom.During operation, with the temperature dial set at #5or less, the distribution fan will not operate. A #5 on thetemperature dial and a #5 on the feed adjuster is approxi-mately 80% output. It is not necessary to operate the distri-bution blower below this point. Therefore, there can be ahigher feed rate ( a larger viewing fire) without an excess ofhot air blowing into the room.An example of when to use the Manual Stove Tem-perature Mode is if you want to watch a large fire and theroom is aleady up to temperature. The Stove TemperatureMode allows you to have a larger fire and a lower soundlevel, without the distribution blower.NOTE: During the use of this mode, if you keepincreasing the temperature dial setting to increase thefire size, the distribution blower will automatically comeon when the ESP Temperature reaches 350o F, or 81%output.NOTE: When starting the unit in the "AUTO"mode and switching to "MANUAL", the fire must belarge enough to start the distribution blower. The start-ing of the blower is a signal that the start cycle is com-pleted and the fire will not go out.MANUAL IGNITION/OPERATIONRoom Temperature Mode: This setting will produce a roomtemperature of 70 degrees with the distribution blower atmedium speed.Fig. 5This setting will produce a large viewing fire withouta distribution blower operating.Manual Stove Temperature ModeWARNING: HIGH VOLTAGEDisconnect power before opening cover.Fig. 6