10 vENTING Only For Qualified Installersburn Only the Fuel for which the Heater isEquippedThe Conquest can burn either natural gas or pro-pane, but requires a change-over kit for natural gas. Thelabel on the burner system module indicates the fuel forwhich it is equipped. A second label, (on the valve) alsoindicates the fuel type.Making The ConnectionThe gas inlet is located on the bottom right side ofthe stove. The inlet fitting is a 1/2” male flare fitting.A separate gas shut-off valve and a /8” N.P.T.plugged tapping should be installed immediately upstreamof the connection to the appliance.The Conquest Direct Vent Gas Heater must be dis-connected from the gas supply piping during any pressuretesting of that system at pressures in excess of / psig(3.5 kPa).The Conquest gas control valve must be in the OFFposition during any pressure testing of the gas supply sys-tem at pressures equal to or less than 1/2 psig (3.5 kPa).WARNING: To avoid pipe compounds fromentering into the gas train, apply compounds onlyto male pipe threads and do not apply compoundto the first two threads.CAUTION: TEST ALL JOINTS FOR LEAKSBEFORE OPERATING.Gas Pressure Requirements:Correct gas pressure and the use of a properly sizedgas supply line are essential for the safe and efficientperformance of this appliance. Make sure that the plumberor gas supplier checks the gas supply line and gas pres-sure at installation.NOTE: Improper gas pressure can affect heaterperformance, flame color, or cause pilot outage.WARNING: This product must be installed by alicensed plumber or gas fitter when installed within theCommonwealth of Massachusetts.Natural Gas:Maximum inlet pressure 7.0” w.c. (.74 kPa)Minimum inlet pressure 5.0” w.c. (1.25 kPa)Gas manifold pressure 3.8” w.c. (0.87 kPa)LP Gas(Propane):Maximum inlet pressure 3” w.c. (3.4 kPa)Minimum inlet pressure 11.5” w.c. (2.74 kPa)Gas manifold pressure ” w.c. (.49 kPa)Do not use this heater if any part has been underwater or exposed to moisture corrosion. Immediatelycall a qualified service technician to inspect the heaterand replace any part of the control system and anygas control which has been under water.Ne pas se servir de cet appareil s’il a étre plongé dansl’eau, complètement ou en partie. Appeler un technicienqualifié pour inspecter l’appareil et remplacer toute partiedu système de contrôle et toute commande qui ont étéplongés dans l’au.If appliance is installed directly on carpeting,tile, or other combustible material other than woodflooring, the appliance shall be installed on a metalor wood panel extending the full width and depth ofthe appliance.Keep areas around air openings into the combus-tion chamber free of obstructions, and do not blockany panels where access is needed for servicing.Pipe Length Schedule 40 Pipe Tubing, Type L(Feet) Inside Diameter Outside DiameterN.G. L.P. N.G. L.P.0-0 /” 3/8” /” 3/8”.3 cm .0 cm .3 cm .0 cm10-40 1/2” 1/2” 5/8” 1/2”.3 cm .3 cm .6 cm .3 cm40-00 /” /” 3/4” /”.3 cm .3 cm .6 cm .3 cm100-150 3/4” 1/2” 7/8” 3/4”.0 cm .3 cm .3 cm .0 cmRECOMMENDED GAS PIPE DIAMETERNOTE: NEvEr USE PLASTIC PIPE. CHECK TO CON-FIrM WHETHEr YOUr LOCAL CODES ALLOW COPPErTUbING Or GALvANIzED PIPE.A LAbEL ON THE bUrNEr SYSTEMMODULE STATES THE FUEL FOrWHICH THE HEATEr IS EQUIPPED.NATURAL GASPROPANE