Top Landing Gate (optional)The optional top landing gate is provided with a combinationmechanical lock and electric contact (interlock).The interlock: Prevents the lift from running if the gate is not closed. Prevents the gate from being opened if the platform isnot at the top landing. Unlocks when the lift is on the upper limit switch.A crescent shaped key is provided to manually unlock the gateduring installation. The key is inserted from the backside to lift up on the solenoid that holds the gatedlocked.Mount the gate by placing onto the upper landingmaking sure to align the gate opening with the platform(outer guard rail not shown for clarity).There are a number of attachment holes provided in thethreshold portion of the gate for mounting using woodlag screws or concrete anchors as appropriate.Remove the latch post cover and connect the call-sendand interlock wire harnesses.The vertical posts of the gate must be attached to asupporting structure, (the gate is not designed to befreestanding).16A length of multi‐conductor wire willneed to be ran from the bottom of the lifttower up to the landing gate. Consultlocal codes for type and mountingrequirements. After wiring is completed,the wiring harness must be plugged intoit appropriate receptacle on thecontroller (ref pg 5).Wiring ConnectionsInterlock Harness Lift HarnessBlack BlackBlack GreenYellow WhiteYellow Orange*Blue* Brown*Must be tied togetherCall‐Send Harness Lift HarnessBlue BlueYellow WhiteRed Red