Electrical Power Connection© 2013 Harmonic Inc. 5 ProView 7000 r.3.2, Rev. AElectrical Power ConnectionThe ProView is powered by an AC power supply. Grounding of the ProView is provided whenthe AC power cable is connected to the unit AC connector.Figure 1: AC ConnectorWhen the ProView is rack-mounted, the device’s grounding jackscrew must be connected tothe rack housing, which must be correctly grounded.DANGER: To avoid electrocution, ensure that the rack has been correctly grounded before switching onthe unit. When removing the unit, remove the grounding connection only after the unit is switched offand unplugged.Ground the unit to the grounding jackscrew with cable 18AWG.CAUTION: This product relies on the building’s electrical installation for short-circuit (overcurrent)protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 20 A U.S. (240 VAC, 20 Ainternational) is used on the phase conductors (all current-carrying conductors).ATTENTION: Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dépend del’installation électrique du local. Vérifier qu’un fusible ou qu’un disjoncteur de 120 V alt., 20 A U.S.maximum (240 V alt., 20 A international) est utilisé sur les conducteurs de phase (conducteurs de charge).WARNUNG: Dieses Produkt ist darauf angewiesen, daß im Gebäude ein Kurzschluß-bzw.Überstromschutz installiert ist. Stellen sie sicher, daß eine Sicherung oder ein Unterbrecher von nicht mehrals 240 V Wechselstrom, 20 A (bzw. in den USA 120 V Wechselstrom, 20 A) an den Phasenleitern (allenstromführenden Leitern) verwendet wird.Grounding Jackscrew