10/6/10 888-2629-200 3-19WARNING: Disconnect primary power prior to servicing.Section 3 OperationMaxiva ULX COFDM Series3.9 System Main MenuIf you press the System button on the GUI screen, it will take you to thescreen shown in Figure 3-14. The System Menu structure is shown inFigure 3-26 on page 3-30.Figure 3-14 System Main MenuThis screen contains the System Main Menu which gives overall status information andaccess to additional System screens. This includes:a. CAB1 - Provides coolant temperatures, air temperatures and coolant flow (litersper minute). The CAB1 block also provides the status of the RF Mute and SafetyInterlocks. Interlocks can read Open (red background) or Closed (gray back-ground)b. Pump Status - Pump icon has a green background color if no faults are present ora red background color if faults are active. For more information on faults press"Faults"c. Pump Control - Pump A & Pump B for dual pump systems are indicated. Thispanel would be grayed out (inactive) for single pump systems. The active pumpwill have a green background. Pumps can be switched from this screen, bypressing A or B only if the pump control panel switch is in the REMOTE mode.Placing the pump control panel in LOCAL mode will disable pump selection onthe System GUI screen. For additional information on LOCAL operation and thepump control panel see "1.2.8.1 Cooling System Control Panel" on page 1-15.AUTO or MANUAL can also be selected here. Selecting AUTO allowsautomatic switchover in case of pump failure in dual pump systems. AUTO is thenormal operating mode if the system has dual pumps.To Figure 3-15To Figure 3-16To Figure 3-17To Figure 3-4