v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts listing in the Problem Determination and Service Guide to determine which components arecustomer replaceable units (CRU) and which components are field replaceable units (FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.Lit light pathdiagnostics LED withthe system-error LEDalso lit Description ActionMEM Memory failure.Note: The error LED on thememory card is also lit.1. Remove the memory card with the lit error LED onthe top of the card; then, press the light pathbutton on the memory card to identify the failedcard or DIMM.2. Reseat the DIMM.3. Replace the following components one at a time,in the order shown, restarting the server each time:a. Memory cardb. DIMMc. (Trained service technician only)Microprocessor trayNMI A hardware error has been reportedto the operating system.Note: The PCI or MEM LED mightalso be lit.1. See the BMC log and the system-error log.2. If the PCI LED is lit, follow the instructions for thatLED.3. If the MEM LED is lit, follow the instructions forthat LED.4. Restart the server.PCI A PCI adapter has failed.Note: The error LED next to thefailing adapter on the PCI-X board isalso lit.1. See the BMC log or the system-error log.2. Reseat the following components:a. Failing adapterb. I/O board3. Replace the components listed in step 2 one at atime, in the order shown, restarting the server eachtime.SP There is a fault in the RemoteSupervisor Adapter II SlimLine. 1. Reseat the Remote Supervisor Adapter II SlimLine.2. Update the firmware for the Remote SupervisorAdapter II SlimLine.3. Replace the Remote Supervisor Adapter IISlimLine.DASD A hard disk drive has failed or hasbeen removed.Note: The error LED on the failinghard disk drive is also lit.1. Reinstall the removed drive.2. Reseat the following components:a. Failing hard disk driveb. SAS hard disk drive backplanec. SAS 6x cabled. I/O board3. Replace the components listed in step 2 one at atime, in the order shown, restarting the server eachtime.Chapter 6. Solving problems 79