M-70053.2 02 (0x02) Read Input StatusThis function code is used to read the thermistor wire openingstatus of a module.Request00 Address 1 Byte 1 to 24701 Function code 1 Byte 0x0202 ~ 03 Starting channel 2 Bytes 0x80 to 0x87, where 0x80corresponds to channel 0, 0x81corresponds to channel 1, etc04 ~ 05 Number of inputchannels2 Bytes N, 1 to 7; (Starting channel + N)should be less than or equal to0x88Response00 Address 1 Byte 1 to 24701 Function code 1 Byte 0x0202 Byte count 1 Byte 103 Data of inputchannels1 Byte A bit corresponds to a channel.When the bit is 1 it denotes thatthe channel is enabled and is eitherover-range, under-range or wireopening. If the bit is 0 it denotesthat the channel is disabled ornormal.Error Response00 Address 1 Byte 1 to 24701 Function code 1 Byte 0x8202 Exception code 1 Byte 02: starting channel out of range03: (starting channel + number ofinput channels) out of range,incorrect number of bytesreceivedi-7005/M-7005 User’s Manual, Rev: B1.8 7MH-018-B18134