IDEC HS1L Series Instruction Sheet
Also see for HS1L Series: Instruction sheet
B-1908-1(0)INSTRUCTION SHEET - HS1L Series Solenoid Type Safety Switch, Inside Connector type( 1 / 6 )2016.082 Specifications and RatingsCAUTIONSolenoid lock type• This safety switch is designed to lock the actuator while the solenoid is energizedand to release it when deenergized.• When the power to the solenoid is interrupted by accident, such as disconnection,the lock is released before a machine stops ompletely. Then, the worker may beexposed to hazards.• This safety switch can be used only for limited applications which do notespecially need to be locked for safety.1 TypeCircuit CodeDQ : 1NC + 1NC 1NO 1NO1NC + 1NCDT : 1NC + 1NC 1NC 1NC1NC + 1NCMaincircuit Door monitorcircuit Lock monitorcircuitEN ISO / ISO14119, GB14048.5IEC60947-5-1, EN60947-5-1GS-ET-19, UL508, CSA C22.2 No.14IEC60204-1/EN60204-1-20 to +55°C (no freezing)2.5AApplicable StandardsStandards for UseMachinery Directive, Low Voltage Direc iveApplicable DirectivesOperatingConditionThermal Current ‹Ith›Contact Ratings( Reference Values )‹Ue, Ie›Operating Temperature45 to 85%RH (no condensation)Operating Humidity3Pollution Degree30V 125V 250VClass of Protection-40 to +80°C (no freezing)Storage TemperatureResistive load (AC-12)Inductive load (AC-15)Resistive load (DC-12)Inductive load (DC-13)DC2.5A 2.5A 2.5AAC 2.5A 2.5A 2.5A2.5A 2.2A 1.1A2.5A 1.1A 0.6AClass II (IEC61140) *1GB14048.52,000m maximumAltitude2 5kV (Between ground and LED, solenoid circuit : 1.5kV)Impulse withstand voltage ‹Uimp›250V (Between ground and LED, solenoid circuit : 30V)Rated insulation voltage ‹Ui›Interlocking device Type/ the level of codedType 2 Interlocking device/ low level coded actuator (EN ISO / ISO14119)0.05 to 1.0 m/s11mm min.50N min.300mΩmax. (Initial value) *5250V, 10A fast acting type fuse *624VDC 100%ED200mA (Initial value)Rated Voltage × 85% max. (at 20 )Rated Voltage × 10% min. (at 20 )Approx. 5W24VDC10mALEDR(Red), G(Green) (Φ12 Lens)Approx. 450g900 operations/hourOperating FrequencyOperating SpeedActuator Tensile Strengthwhen LockedDirect Opening TravelDirect Opening ForceContact ResistanceShort-circuit protective deviceRated Operating VoltageRated CurrentTurn ON VoltageTurn OFF VoltageRated Power ConsumptionRated Operating VoltageRated CurrentLight SourceLens ColorWeightDamage Limits 1,000m/s2Operating Extremes 10 to 55 Hz, half amplitude 0 35 mmDamage Limits 30 Hz, half amplitude 1.5 mmElectrical Durability1,000,000 operations min. (GS-ET-19)Ind c v loa ( 1 1A 0 6A2,000,000 (EN ISO 13849-1 Annex C Table C.1)B10dMechanical Durability100,000 operations min.(900 operations / hour, Rated Load)(900 operations / hour, 24V AC/DC 0.1A Resistive Load)1,000,000 operations min.IP67 (IEC60529)Degree of Protection100A (250V)Conditional short circuit currentSolenoidIndicatorShock ResistanceVibration ResistanceFzh=3,000N minimumF1max.=3,900N minimum (GS-ET-19) *2, *3, *4Ratings approved by safety agencies(1) TÜV ratingAC-15 250V, 2.5ADC-13 30V, 2.5A(2) UL , c-UL rating2.5A, 250V ac, General Use2.5A, 250V ac, Resistive2.5A, 30V dc(3) CCC ratingAC-15 2.5A, 250V acDC-13 2.5A, 30V dc*1 Basic insulation of 2.5kV impulse withstand voltage is ensured between differentcontact circuits and between contact circuits and LED or solenoid in the enclosure.When both SELV (safety extra low voltage) or PELV (protective extra low voltage)circuits and other circuits (such as 230V AC circuits) are used for the solenoidpower and contact circuits at the same time, the SELV or PELV requirements arenot met any more.*2 See item 8 Dimensions.*3 The actuator locking strength is rated at 3,000N of sta ic load. Do not apply a loadhigher than the rated value. When a higher load is expected to work on theactuator, provide an additional system consisting of another safety switch withoutlock (such as the HS5D safety switch) or a sensor to detect door opening and stopthe machine.*4 F1max. is maximum force. The actuator’s guard-locking force Fzh is calculated inaccodance with GS-ET-19:*5 When applicable connector and 1m cable (0.3mm 2 AWG22) are connected.*6 Make sure that a fast acting fuse for short-circuit protection trips before overheatingof the wires.Fzh = maximum force (F1max )Safety coefficient (=1.3)Thank you for purchasing this IDEC product. Confirm that the delivered product iswhat you have ordered. Read this instruction sheet to make sure of correct operation.In this operation instruction sheet, safety precautions are categorized in order ofimportance to Warning and Caution :Warning notices are used to emphasize that improper operation may cause severepersonal injury or death.Caution notices are used where inattention might cause personal injury or damage toequipment.INSTRUCTION SHEETOriginal InstructionsSolenoid Type Safety SwitchHS1L SeriesInside Connector typeS A F E T Y P R E C A U T I O N SCAUTIONWARNINGSolenoid voltage / Lock Mechanism4 : 24V DC / Spring Lock7Y : 24V DC / Solenoid LockIndicator voltage4 : 24V DC[0] : Without IndicatorConduit Typeblank : G1/2P : PG13.5M : M20Body ColorR : Red/BlackIndicator ColorG : GreenR : RedHS1L-DQ44KMSRPC-GActuator Tensile Strengthwhen LockedMS : 3,000NManual unlock key[blank] : Without Manual Unlock KeyK : With Manual Unlock KeyType Nos. in [ ] are not supplied as standard.Contact IDEC if required.Wiring methodC : With Connector |
Related manuals for IDEC HS1L Series
IDEC HS1L Series Instruction Sheet
IDEC HS1T Series Instruction Sheet
IDEC HS1C Series Instruction Sheet
IDEC HS6B Series Instruction Sheet
IDEC HS5L Series Instruction Sheet
IDEC HS5E Series Instruction Sheet
IDEC HS6B Series Instruction Sheet
IDEC HS6E Series Instruction Sheet
IDEC SX5E Series Instruction Sheet
IDEC SX5E Series Instruction Sheet
manualsdatabase
Your AI-powered manual search engine