IDEC HS6E Series Instruction Sheet
B-1906-1(0)INSTRUCTION SHEET - HS6E Series Solenoid Type Safety Switch( 1 / 6 )2016.081 Type2 Specifications and RatingsCAUTIONSolenoid lock type• This safety switch is designed to lock the actuator while the solenoid is energizedand to release it when deenergized.• When the power to the solenoid is interrupted by accident, such as disconnection,the lock is released before a machine stops ompletely. Then, the worker may beexposed to hazards.• This safety switch can be used only for limited applications which do not especiallyneed to be locked for safety.Ratings approved by safety agencies(1)TÜV ratingMain circuit, Look monitor circuitAC-15 125V/1ADC-13 125V/0.22ADC-13 30V/1ADoor monitor circuitAC-15 240V/0.75ADC-13 250V/0.27ADC-13 30V/2.3A(4) KOSHA ratingMain circuit, Look monitor circuitAC-15 125V/1ADC-13 125V/0.22ADoor monitor circuitAC-15 240V/0.75ADC-13 250V/0.27A(2) UL, c-UL ratingMain circuit,Look monitor circuit1A, 125V ac, Pilot Duty0.22A, 125V dc, Pilot Duty1A, 30V dc, Pilot DutyDoor monitor circuitC300 0.75A, 240V ac, Pilot DutyQ300 0.27A, 250V dc, Pilot Duty(3) CCC ratingMain circuit, Look monitor circuitAC-15 125V/1ADC-13 30V/1ADoor monitor circuitAC-15 240V/0.75ADC-13 30V/2.3A*1 Basic insulation of 2.5kV, 1.5kV impulse withstand voltage is ensured betweendifferent contact circuits and between contact circuits and LED or solenoid in heenclosure. When both SELV (safety extra low voltage) or PELV (protective extralow voltage) circuits and other circuits (such as 230V AC circuits) are used for hesolenoid power and contact circuits at the same time, the SELV or PELVrequirements are not met any more.*2 The actuator locking strength is rated at 500N of static load. Do not apply a loadhigher than the rated value. When a higher load is expected to work on theactuator, provide an additional system consisting of another safety switch withoutlock (such as the HS6B/HS7A safety switch) or a sensor to detect door openingand stop the machine.*3 F1max. is maximum force. The actuator’s guard-locking force Fzh is calculated inaccodance with GS-ET-19:*4 Make sure that a fast acting fuse for short-circuit protection trips beforeoverheating of the wires.Main Door Monitor Lock MonitorCircuit Circuit CircuitL : 1NC+1NC 2NC 1NOM : 1NC+1NC 2NC 1NCN : 1NC+1NC 1NC, 1NO 1NOP : 1NC+1NC 1NC, 1NO 1NCVL : 3NC 1NC, 1NOVM : 3NC 2NCVN : 2NC, 1NO 1NC, 1NOVP : 2NC, 1NO 2NCSolenoid Voltage / Lock Mechanism4 : 24V DC / Spring Lock7Y : 24V DC / Solenoid LockIndicator Voltage4 : 24V DCCable Length01 : 1m03 : 3m05 : 5mPilot Light ColorG : GreenCircuit CodeHS6E-L44B01-GHousing ColorB : BlackConfirm that the delivered product is what you have ordered.Read his instruction sheet to make sure of correct operation.In this operating instruction sheet, safety precautions are categorized to Warning andCaution:Warning notices are used to emphasize that improper operation may cause severepersonal injury or death.Caution notices are used where inattention might cause personal injury or damage toequipment.INSTRUCTION SHEETOriginal InstructionsSolenoid Type Safety SwitchHS6E SeriesS A F E T Y P R E C A U T I O N SCAUTIONWARNING * In order to verify if the productyou are interested in is certifiedwith the S mark, please checkthe following section on ourwebsite: "List of type numberscertified with the S mark"(Main circuitDoor monitor circuit)Interlocking device Type/the level of coded Type 2 Interlocking device/ low level coded actuator (EN ISO / ISO14119)Resistive load(AC-12)Inductive load(AC-15)ACMainCircuit,Lookmonitorcircuit30V 125V 250V- 2A -- 1A -‹Ue, Ie›Contact RatingsThermal Current ‹Ith›Rated Insulation voltage ‹Ui›Impulse withstand voltage ‹Uimp›AltitudePollution degreeOperating HumidityCondition Operating TemperatureApplicable DirectivesStandards for UseApplicable Standards0.5A (≥ 2 circuits)1.0A (1 circuit)35°C ≤ Operating temperature ≤ 50°C1.0A (≥ 3 circuits)2.5A (≤ 2 circuits)-25°C ≤ Operating temperature < 35°C30V(Between ground and LED,solenoid circuit)300V(Door monitor circuit)150V(Main,Lock monitor circuit)0.5kV(Between ground and LED,solenoid circuit)2 5kV(Door monitor circuit)1 5kV(Main,Lock monitor circuit)2,000m maximum3(Inside 2)45 to 85%RH(no condensation)-25 to +50°C (no freezing)Machinery Directive, Low Voltage DirectiveIEC60204-1, EN60204-1GS-ET-19, UL508, CSA C22.2 No.14IEC60947-5-1, EN60947-5-1EN ISO / ISO14119, GB14048.5Fzh = maximum force (F1max.)Safety coefficient (=1.3)Rated Power ConsumptionIllumination ColorLight SourceTurn OFF VoltageTurn ON VoltageRated CurrentRated Operating VoltageResistive load(DC-12)Inductive load(DC-13)Resistive load(AC-12)Inductive load(AC-15)Resistive load(DC-12)Inductive load(DC-13)DCACDCDoormonitorcircuit-2A 0.4A -1A 0.22A -- 2.5A 1.5A- 1.5A 0.75A2.5A 1.1A 0.55A2.3A 0.55A 0.27AApprox. 2.7WGreenLEDRated voltage x 10% minimum (at 20°C)Rated voltage x 85% maximum (at 20°C)110 mA (solenoid 100mA, LED 10mA : initial value)DC24V 100% duty cycleRated Operating Voltage DC24V 100% duty cycleUse 250V / 10A fast acting type fuse *450A (250V)NEMA Type12 (operating temp. -25 to 45°C)IP67 (IEC60529)300 m Ω maximum (initial value, 1m cable)60 N minimum8 mm minimum24V AC/DC 0.1A Resistive Load)(900 operations / hour,1,000,000 operations minimum.AC-12 125V 2A, DC-12 125V 0.4A)(900 operations / hour,100,000 operations minimum.1,000,000 operations minimum. (GS-ET-19)2,000,000 (EN ISO 13849-1 AnnexC Table C.1)0.05 to 1.0 m/s900 operations/hourClass II (IEC61140) *1Short-circuit Protective DeviceConditional short circuit currentDegree of ProtectionContact ResistanceDirect Opening ForceDirect Opening TravelActuator Tensile Strengthwhen LockedElectrical DurabilityMechanical DurabilityB10dOperating SpeedOperating FrequencyClass of ProtectionShock ResistanceVibration ResistanceOperating Extremes: 100m/s2, Damage Limits: 1,000m/s2Operating Extremes:10 to 55 Hz, half amplitude 0.35mmDamage Limits: 30 Hz, half amplitude 1 5mmFzh=500N minimumF1max.=650N minimum (GS-ET-19) *2, *3(Fzh=100N minimum: HS9Z-A62 actuator)SolenoidIndicator※ |
Related manuals for IDEC HS6E Series
IDEC HS6B Series Instruction Sheet
IDEC HS6B Series Instruction Sheet
IDEC HS5E Series Instruction Sheet
IDEC HS5L Series Instruction Sheet
IDEC HS1L Series Instruction Sheet
IDEC HS1L Series Instruction Sheet
IDEC HS1T Series Instruction Sheet
IDEC HS1C Series Instruction Sheet
IDEC SX5E Series Instruction Sheet
IDEC SX5E Series Instruction Sheet
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine