14NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.3"/76mm3"/76mm3"/76mm1-1/2”38mm31-1/2”800mm33-1/2”851mm36-1/2”927mm39-1/2”1003mmIMPORTANT: If unit is converted to an RDV33 / SDVI33 froman RDV40 / SDVI40, the clearances to combustibles can bereduced as shown on this page.WARNING: If this unit is ever converted back to an RDV40 /SDVI40, ensure that the clearances are correct for this model.Minimum Clearances to CombustiblesMinimum clearances include any projections such as shelves, windowsills, mantels, spacers/standoffs or surfaces to combustible constructionetc. above the appliance. Paint or lacquer used to finish the mantelmust be heat resistant in order to avoid discoloration.The letters in Figure 5 (A through E) show minimum clearances requiredfrom the appliance to combustibles and the minimum projection of thehearth extension.Insert LevelingAt each front and rear corner of the insert is an adjustable leg providedto level the insert should the hearth of the fireplace be uneven. To adjustthe legs, loosen the two 5/32" allen head screws, move the leg to thedesired height and then tighten the screws. Repeat these steps for eachadjusting leg.Facing and Mantel ClearancesPlease note that the RDV33 / SDVI33 mantel clearances are 4" less thanthe RDV40 / SDVI40 mantel clearances as shown in Figure 4A - RDV40/ SDVI40 and Figure 4B - RDV33 / SDVI33.CLEARANCES TO COMBUSTIBLESRDV40 / SDVI40Facing and MantelSide ViewRDV33 / SDVI33Facing and MantelSide ViewHearth ProtectionFigure 4AFigure 5 - ClearancesFigure 4BMINIMUM CLEARANCESNOTE: Hearth protection to be min.3/8” (10mm) thick non-combustibleor equivalent, with a k factor of .84.ADBECCLMANTELTRIMMINIMUM CLEARANCES TO COMBUSTIBLES .......... RDV40 / SDVI40 RDV33 / SDVI33A = Top Facing to Bottom of Appliance ..................... 35-1/2" (902mm) 31-1/2" (800mm)B = Side Facing or Side Wall to Center of Glass ...... 25-1/2" (648mm) 25-1/2" (648mm)C = 10-1/2” (267mm) Mantel to Bottom of Appliance. 43" (1092mm) 39" (991mm)HEARTH PROTECTIOND = Vertical Distance from base of appliance 0" 2” 4” 0" 2” 4”to Hearth Extension .......................................... (0mm) (51mm) (102mm) (0mm) (51mm) (102mm)E = Minimum Horizontal Distance 14" 10” 0” 13" 10” 0”from Front of Appliance.................................. (356mm) (254mm) (0mm) (330mm) (254mm) (0mm)MANTELFACINGFront ViewLeftSideRightSide3"/76mm3"/76mm3"/76mm1-1/2”38mm31-1/2”800mm33-1/2”851mm36-1/2”927mm39-1/2”1003mm1-1/2”38mm31-1/2”800mm33-1/2”851mm36-1/2”927mm39”991mm3"/76mm3"/76mm3"/76mm1-1/2”38mm35-1/2”902mm37-1/2”953mm40-1/2”1029mm43”1092mm3"/76mm3"/76mm3"/76mm