SUOMI / ENGLISH11Maximum Session TimeThe maximum sauna session time depends on the purpose of the sauna. For domesticuse, the total on-time of the sauna is limited to 6 hours. *)It includes pre-run timeand the session time. The factory setting for the control unit is 6 hours.For condominiums, hotels and similar locations, the operating period of the saunaheater is limited to 12 hours, including the pre-run time and the session time.For public sauna, the operating period of the sauna heater can be either 18 or 24hours. Please note, if the public sauna is set to 24 hours, it will be on constantly. Itneeds to be continuously attended.The maximum heater on-time is set by the jumpers on SCB1 in the power controller,see the Fig. 5. Jumpers 3, 4 and 5 are meant only for public sauna rooms. Only aqualified electrical can change the settings. The standards and regulations of thecountry where the control unit is installed must be followed, when setting thejumpers. When no jumpers are placed, the default time is 6 hours. See the Table.*) IEC 60335-2-53Sauna Type Domestic sauna Hotels, Condominiums Public saunaJumper 1 2 3 4 54h 6h3h 5h12h99h18h 24hMax. timeMax. pre-run time* See Fig.5 on Page 8.The heater main switch can be found on thelower part of the heater. Using this switch, youcan isolate the electronics from the mains powersupply.In order to put the unit into operation, switch tothe first position (switch position I). In thisswitch position all control unit’s functions worknormally.In case of breakdown, press the control unitswitch on the left part of the rocker to themiddle position (switch position 0). The unit isnow completely switched off.In order to switch on the light in the saunawhen the unit is switched off, press on the leftpart of the rocker to the second position (switchposition II).The Heater Main Switch0II I0 ===IIIOFFLIGHT ONUNIT ON