5 - 75-4 RECEIVE ADJUSTMENTS1) Select an adjustment item using [↑]/[↓] on the PC's keyboard.2) Set or modify the adjustment value as specifi ed using [←]/[→] on the PC's keyboard, then push [ENTER].ADJUSTMENT TRANSCEIVER’SCONDITION OPERATION ADJUSTMENTITEM VALUERX SENSITIVITY 1 • CH. : 11• Receiving1) C o n n e c t a n S S G t o t h e a n t e n n aconnector and set it as;Frequency : 136.000 MHzLevel* : 20 dBμ (–87 dBm)Modulation : 1 kHzDeviation : ±3.0 kHz2) Put the cursor on the adjustment item,then push [ENTER].[BPF ALL]( A u t o m a t i cadjustment)SQUELCH 1 • CH. : 11• Receiving1) C o n n e c t a n S S G t o t h e a n t e n n aconnector and set it as;Frequency : 136.000 MHzLevel* : –13 dBμ (–120 dBm)Modulation : 1 kHzDeviation : ±3.0 kHz2) Once close the squelch by increasing[SQL] value, then decrease the value toopen the squelch.3) Push [ENTER] to store the value.[SQL]( A u t o m a t i cadjustment)*; The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.