5 - 1SECTION 5 ADJUSTMENT PROCEDURES+ Audio generator300 Hz to 3 kHzACmillivoltmeterMICEMICPTTPTT switchPTTEAdd a jumper wire hereElectrolyticcapacitor47 FOPC-1122(Cloning cable)5-1 PREPARATIONWhen you adjust the contents on pages 5-5 and 5-6, SOFT-WARE ADJUSTMENT, the optional CS-F100 ADJ ADJUST-MENT SOFTWARE (Rev. 1.0 or later), *OPC-1122 JIG CABLE(modified OPC-1122 CLONING CABLE ; see illustration below)are required. SYSTEM REQUIREMENTS• IBM PC compatible computer with an RS-232C serial port(38400 bps or faster).• Microsoft Windows 95/98 or Windows ME• Intel Pentium 100 MHz processor or faster• At least 16 MB RAM and 10 MB of hard disk space• 640×480 pixel display (800×600 pixel display recommend-ed) ADJUSTMENT SOFTWARE INSTALLATIONq Boot up Windows.- Quit all applications when Windows is running.w Insert the ‘CS-F100’ into the appropriate CD drive.e Select ‘Run’ from the [Start] menu.r Type the setup program name using the full path name,then push [Enter] key.(ex. D:\CSF100ADJ\Setup.exe)t Follow the prompts.y Program group ‘CS-F100 ADJ’ appears in the ‘Programs’folder of the [Start] menu. STARTING SOFTWARE ADJUSTMENTq Connect IC-F110 and PC with *OPC-1122 JIG CABLE .w Turn the transceiver power ON.e Boot up Windows, and click the program group ‘CS-F100ADJ’ in the ‘Programs’ folder of the [Start] menu, thenCS-F100 ADJ’s window appears.r Click ‘Connect’ on the CS-F100 ADJ’s window, thenappears IC-F110’s up-to-date condition.t Set or modify adjustment data as desired.IBM is a registered trademark of International BussinessMachines Corporation in the U.S.A. and other countries.Microsoft and Windows are registered trademarks ofMicrosoft Corporation in the U.S.A. and other countries.Screen shots produced with permission from MicrosoftCorporation. All other products or brands are registeredtrademarks or trademarks of their respective holders.• *OPC-1122 (JIG CABLE)