2Classic SE RS - Userse.Flammable materials must not be placed in close proximity tothe appliance. Materials giving off flammable vapours must notbe stored in the same room as the appliance.f. Under NO circumstances should any of the sealed componentson this appliance be used incorrectly or tampered with.Minimum clearancesA clearance of 533mm (21") MUST be available at the front of theboiler for servicing.The minimum clearances given below MUST be complied with inorder to maintain the safe running of the boiler .Above the boiler 100 mm (4")At each side of the boiler 5 mm ( 1/4 ")Underneath the boiler 100 mm (4")In front of the boiler 75 mm (3")To light the boiler. Refer to Frame 1If a programmer is fitted, refer to separate instructions for theprogrammer before continuing.1. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER IS OFF.2. Open the controls access door by hinging downwards.3. Ensure that the gas inlet cock (C) is OPEN.4. If an overheat thermostat is fitted press the overheat reset button(D), located as shown in Frame 1.5. Switch ON the electricity supply to the boiler. Check that all externalcontrols, e.g. room thermostat etc., are ON.6. Turn the boiler thermostat knob (B) to position 6. After about 15seconds the boiler will light automatically - this can be viewedthrough the sightglass (A).Set the boiler thermostat to the desired position.7. Close the controls access door.INTRODUCTIONIt is essential that the instructions in this booklet arestrictly followed, for safe and economic operation ofthe boiler.Current Gas Safety (Installation & Use)Regulations or rules in force.In your own interest, and that of safety, it is the law thatthis boiler must be installed by a CORGI registered installeror in IE a competent person, in accordance with the aboveregulations.Electricity SupplyThis appliance must be efficiently earthed.Supply: 230 V ~ 50 Hz. The fusing should be 3A.Connection must be made in a way that allows completeisolation of the electrical supply such as a double pole switchhaving a 3mm (1/8") contact separation in both poles, or aplug and socket, serving only the boiler and system controls.The means of isolation must be accessible to the user afterinstallation.IMPORTANT NOTESa.This appliance must not be operated without the casingcorrectly fitted and forming an adequate seal.b.If the boiler is installed in a compartment then thecompartment MUST NOT be used for storage purposes.c.The ventilation provided for the boiler during installation MUSTNOT be blocked and a check should be made periodicallythat the ventilation areas are free from any obstruction.d.If it is known or suspected that a fault exists on the boiler thenit MUST NOT be used until the fault has been corrected by aCORGI registered installer or in IE a competent person.CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning ofthis appliance, care should be taken when handling edges of sheet steel components.Model GC Appliance NoClassic SE9 RS ........................... 41 395 44Classic SE12 RS ......................... 41 395 45Classic SE15 RS ......................... 41 395 46Classic SE18 RS ......................... 41 395 99Classic SE RS (Natural Gas Models Only)