Frost protectionIf no frost protection is provided and frost is likely during a shortabsence from home, leave the heating controls (if fitted) at areduced temperature setting. For longer periods, the entiresystem should be drained.If the system includes a frost thermostat then, during coldweather, the boiler should be turned OFF at the time switch (iffitted) ONLY. The mains supply should be left switched ON, withthe boiler thermostat left in the normal running position.Boiler overheat thermostatThis thermostat will shut down the boiler in the event ofoverheating. Should this occur a fault code will be displayed.Press the reset button (D) and the boiler will re-light.If the fault re-occurs, turn off the boiler and consult a CORGIregistered installer.Flame failureShould this occur a fault code will be displayed. Press thereset button and the boiler will relight. If the fault recurs, turn offthe boiler and consult a CORGI registered installer.Loss of system water pressureThe gauge (H) indicates the central heating system pressure. Ifthe pressure is seen to fall below the original installation pressureof 1-2 bar over a period of time then a water leak is indicated. Inthis event a CORGI registered installer should be consulted.Ideal Consumer Helpline Tel: 01482 498 660www.idealboilers.comCaradon Plumbing Ltd.pursues a policy of continuingimprovement in the design andperformance of its products. Theright is therefore reserved to varyspecification without notice. April 2001 UIN 156415 A01The code of practice for the installation,commissioning & servicing of central heating systemsCaradon Plumbing Ltd. is a member of the Benchmarkinitiative and fully supports the aims of the programme.Benchmark has been introduced to improve the standards ofinstallation and commissioning of central heating systems inthe UK and to encourage the regular servicing of all centralheating systems to ensure safety and efficiency.Caradon Plumbing Ltd.P.O. Box 103, National Ave,Kingston upon Hull, HU5 4JN.Telephone: 01482 492 251Fax: 01482 448 858.Registration No. London 322137.DO NOT FIRE THE BOILER IF THE PRESSURE HASREDUCED TO ZERO FROM THE ORIGINAL SETTING.Condensate DrainThe condensate drain (G) must not be modified or blocked.Blockage of the condensate drain, caused by debris or freezing,can cause automatic shutdown of the boiler.If freezing is suspected and the pipe run is accessible an attemptmay be made to free the obstruction by pouring hot water overthe exposed pipe and clearing any blockage from the end of thepipe. If this fails to remedy the problem the assistance of aCORGI registered installer should be sought.Escape of gasShould a gas leak or fault be suspected contact your local gassupplier without delay.Do NOT search for gas leaks with a naked flame.CleaningFor normal cleaning simply dust with a dry cloth.To remove stubborn marks and stains, wipe with a damp clothand finish off with a dry cloth.DO NOT use abrasive cleaning materials.MaintenanceThe appliance should be serviced at least once a year by aCORGI registered installer.