AM-1600GE / AB-1600GE378.6.4 Partial ScanningThe timing for the partial scan mode in normal continuous mode is shown below. Vertical TimingThe diagram below provides the vertical timing information.Frame rate calculation formulaThe frame rate can be calculated using the following formula.In this formula, “Ceil” is round up. And(Top_Dump_line + Partial lines +Bottom_Dump_line)=3248Total lines = 59 + A_line + Partial lines + B_line + 20Frame Rate (fps) = 1 / (2960 * Total lines * 33.333333 / 1000000000)Where,A _line Ceil{(Top_Dump_line + 3)/12}, If Top_Dump_Line is 0, A_line is 0.B_line Ceil{(Bottom_Dump_line + 3)/12}, If Bottom_Dump_line is 0, B_line is 0.Example:Case Partial lines Start line H period(clock)V period(Lines)Frame rate(fps) Calculation1 1/2 (1624) 0 2960 1839 5.51 59+0+1624+136+202 1/2 (1624) 812 2960 1839 5.51 59+68+1624+68+203 1/2 (1624) 1624 2960 1839 5.51 59+136+1624+0+204 1/4(812) 0 2960 1095 9.25 59+0+812+204+205 1/4(812) 812 2960 1095 9.25 59+68+812+136+206 1/4(812) 2436 2960 1095 9.25 59+204+812+0+20Fig. 23 Vertical timing for partial scanningLVALFVALDVALDATAEENXEENValid DataCCD Exposure3LA B C