CV-L108CL358.37 Serial communicationThe CV-L108CL can communicate by serial communication via the Camera Link connectoror via RS232C in the 12-pin Hirose connector. The Baud Rate is fixed at 9600 bps.Switch SW1 at the rear panel of the camera is used to select which way the serialcommunication is set up.SW1No Function SettingOFF ON1 Select serial communication path Hirose 12Pin Camera link2 External trigger input termination 75 ohm TTLNote: HIROSE 12 Pin and Camera Link can not be used simultaneously.Communication setting:Protocol.Transmit setting to camera:NN=[Parameter] (NN is any kind of command. Capital or small letters.)The camera answers:COMPLETETo have all communication visible on the emulator screen, start with:EB=1The camera answers:COMPLETETransmit request command to camera:NN? (NN is any kind of command.)The camera answers:NN=[Parameter]Transmit the following to have the camera actual setting:ST?The camera answers:A complete list of the current settingsBaud Rate 9600Data Length 8bitStart Bit 1bitStop Bit 1bitParity NonXon/Xoff Control Non12Serial comm.HR ⇔ CL75ΩON ⇔ OFF12