Page 9Configuring the TM-4100GE CameraTM-4100GE Software3 Configuring the TM-4100GE CameraThe configuration of your GigE camera consists of two parts:• The imager configuration (CCD and control circuits)• The internal frame grabber configurationThe imager can be configured for partial scan, binning, and so on, just like a Camera Link camera. Theinternal frame grabber is automatically configured for the pixel type, windowing, image size, I/O and soon, by the GigE camera software.3.1 SetupIf you have a peer-to-peer connection between the TM-4100GE camera and your PC without networkswitches, your packet size can be the default value (8128 bytes) as shown in Figure 7. However, if youare connecting the TM-4100GE to your PC through a network switch, then you need to know themaximum packet size that your network switch supports. Typically, if your switch supports jumbopackets, then you should keep the packet size to 8128 bytes. If your switch does not support jumbopackets, then you may need to change the packet size to 1440 bytes.FIGURE 9. Camera Interface Application Dialog BoxNote: If you connect thecamera through a networkswitch, you may need tomodify the packet size.