7Figure 8Clearance to Combustibles:A) TOP: from top of grate to any combustibles* above unit: 5 feet minimum*Such as decks, ceilings, hanging plants, etc.B) REAR: from rear of unit to any combustibles behind unit: 6 inches minimumC) SIDE: from the outside edges of the unit to any adjacent combustibles: 6 inches minimumLEAK TESTING:STEP 1Mix a solution of liquid dish soap and water (or obtain profession leak detector liquid).Turn on Gas.STEP 2Spray or brush detector liquid thoroughly on all fuel line connections (Fig.8). If soapbubbles are generated at any connection, tighten the fitting and re-test. If a leak isdetected that cannot be successfully repaired, immediately turn off the gas and contactyour dealer for further assistance.LIGHTING INSTRUCTIONS:1. Turn the main gas supply ON.2. Depress the side burner control knob down slightly and turn SLOWLY counter clock wise until the ‘click’ ofthe igniter is heard. (This side burner has a built in ignition system).3. If the side burner does NOT light, turn the control knob to the OFF position and try again.4. Once the burner has lit, turn the control knob counter clock wise to the desired heat level.NOTE: To turn the unit off, turn the gas control clockwise to the OFF position.!WARNING!Please allow extra space when the unit is backed up to vinyl siding;exhaust exiting the rear of the unit can warp or melt the vinyl.