23J-300 seriesJ-300 Series9.0 Control Functions9.1 Control panelA. leD Display: Candisplay current watertemperature (defaultdisplay), watertemperature set point,selected filtration/heating mode, and errormessages.B. warmer ( ) Button: Increases water temperature set point.C. Cooler ( ) Button: Decreases water temperature set point.D. light on/off Button options: Turns waterfall, footwell light,lighted cup holders and backlit pillows on in unison. Press once forhigh intensity; press a second time for medium intensity; press a thirdtime for low intensity; press a fourth time to turn off. The displayedcolor is changed using the light mode button (E) below.E. light mode Button: Selects one of 4 color modes for waterfall,footwell, cup holders, and pillow lights. See page 26 for additioninformation.F. Jets 1 Button: Turns jets pump #1 on and off. Press once for lowspeed; press a second time for high speed; press a third time to turnpump off.G. Jets 2 Button (J-335 to J-375): Turns high-speed jets pump #2 onand off. Press once to turn pump #2 on; press a second time to turnpump #2 off.H. Heat Indicator: Lit when heater is on.operation DetailsTemperature Adjustment: 65 to 104 °F (18 to 40 °C). Factory default•setting is 100 °F (38 °C).Light Operation: All LED lights run for 2 hours, then automatically•shut off.Jets 1/Jets 2 Button Operation: Jets run for 20 minutes when•activated, then turn off automatically to conserve energy. Simplypress either jets button to continue operation for an additional 20minutes.HA2-Pump Control Panel ShownDBC EGF23