page 314.6 Panel Displays ICEFreeze Protection - A potential freeze condition has beendetected. No action is required. The pump and heater willoperate to circulate and warm water through the plumbinguntil spa is out of danger. See “Winterizing” (page 28).14.7 Panel Displays OHWater temperature is above acceptable limits. Do not enterspa! Water temperature has reached 112˚F (44˚C) and thelow speed pump has activated to circulate water throughheater. Contact your authorized Jacuzzi dealer or qualifiedservice technician.14.8 Panel Displays - - -The safety “Watchdog” software has been triggered andthe spa is deactivated. A problem has been detected whichcould cause damage to the spa or its components. Contactyour authorized Jacuzzi dealer or qualified service techni-cian.15.0 Troubleshooting ProceduresIn the event your Jacuzzi® spa is not working the way it should, pleasefirst review all the installation and operating instructions in this manualand check the message on the panel display. If you are still not satis-fied it is working properly, please follow the appropriate troubleshootinginstructions below. Note: If any of the supply cords to the accessoriesare damaged, they must be replaced by authorized service personnel.Contact your authorized Jacuzzi dealer or qualified service technician.15.1 None of the Components Operate (e.g. Pump, Light)Check the following:. Is there power to the spa?2. Is the household circuit breaker tripped?3. Contact your authorized Jacuzzi dealer or qualified servicetechnician.15.2 Pump Does Not Operate but Light DoesPress the JETS button:. If no water movement is detected, make sure power is going to thespa and check the water level. If it does not solve the problem, con-tact your authorized Jacuzzi dealer or qualified service technician.2. The main pump operates but no water flows to jets. Pump may notbe properly primed. This can happen after the spa is drained and