Page 6Section 3. Installing Jandy Light Fixture during New Construction3.1 Preparing the Light Fixture for InstallationNOTE The electrician must complete preparatory steps before light fixture is installed; see Figure 1 (or Figure 2, forspa).1. Ensure that the pool or spa meets the requirements of the current National Electrical Code and all localcodes and ordinances. A licensed or certified electrician must install the electrical system to meet orexceed those requirements before the underwater light is installed. Some of the requirements of theNational Electrical Code, which the pool or spa’s electrical systems must meet, are as follows:a.a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) for line voltage 120 voltThe lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) for line voltage 120 voltmodels, and must have an appropriately rated circuit breaker.models, and must have an appropriately rated circuit breaker.b.b. The Junction Box (or, for 12 volt models, the low voltage transformer) must be located at leastThe Junction Box (or, for 12 volt models, the low voltage transformer) must be located at leasteight (8) inches above water level, at least four (4) inches above ground level, and at least four (4)eight (8) inches above water level, at least four (4) inches above ground level, and at least four (4)feet from the edge of the pool or spa; see Figure 1 for pools and Figure 2 for spas.feet from the edge of the pool or spa; see Figure 1 for pools and Figure 2 for spas.c.c. The light fixture and all metal items within five (5) feet of the pool or spa must be properlyThe light fixture and all metal items within five (5) feet of the pool or spa must be properlyelectrically bonded to a reliable point of grounding.electrically bonded to a reliable point of grounding.d.d. The wet niche must be properly installed so that the top edge of the underwater light’s lens is atThe wet niche must be properly installed so that the top edge of the underwater light’s lens is atleast 18 inches below the surface of the water in the pool or spa; see Figure 1 or 2. (Not more thanleast 18 inches below the surface of the water in the pool or spa; see Figure 1 or 2. (Not more than48 inch depth in Canada.)48 inch depth in Canada.)e.e. The wet niche must be properly electrically bonded and grounded via the No. 8 AWG groundThe wet niche must be properly electrically bonded and grounded via the No. 8 AWG groundconnector located at the rear of the niche; see Figure 1 or 2.connector located at the rear of the niche; see Figure 1 or 2.NOTE The pool or spa electrical system can be verified with a Pool and Spa Electrical Qualification Test kit. The testkit is available from local distribution. The electrical system inspection using this kit must be performed bytrained and certified personnel.Figure 1. Jandy Digital Pool Light#8 AWG GroundConnector bondingis located at rear ofNiche.RigidConduitTo GFCI, CircuitBreaker andPower Source.4" min.48"min.8" min. Junction Box or LowVoltage Transformer, maximumwater level of the pool.18" min. to top of Lens.Concrete must be cutback around Niche toallow for a compactedplaster seal.Coil 4 ft. of light cablearound Fixture.11.50"16"