4Cabinet Dimensions*NOTE: Grills installed near a side wall must allow a minimumclearance of 6" (15.2 cm) between cooktop and sidewall formaximum performance. Minimum clearance of 1" (2.5 cm) isrequired to sidewalls and ¾" (1.9 cm) to rear wall.NOTES: After making the countertop cutout, some installationsmay require notching down the base cabinet side walls to clearthe cooktop base. To avoid this modification, use a base cabinetwith sidewalls wider than the cutout.■ Where possible, a 6" (15.2 cm) clearance is recommended formotor blower service. A minimum clearance of 1" (2.5 cm) isrecommended to the sidewalls and a ³⁄₄" (1.9 cm) clearance isrecommended to the rear wall.■ A minimum clearance of 2" (5.1 cm) is recommendedbetween the motor/blower and cabinet for proper cooling.■ A minimum clearance of 6¹⁄₄" (15.9 cm) is recommended forremoval of the grease container(s). Installed dimension for thegrease containers is 5¹⁄₂" (14.0 cm).■ For grills installed near a sidewall, a minimum clearance of6" (15.2 cm) is recommended between the cooktop andsidewall for maximum performance.Cutout DimensionsVenting Requirements■ Do not terminate the vent system in an attic or other enclosedarea.■ Use a Jenn-Air® vent cap.■ Vent system must terminate to the outside.■ Use only a 6" (15.2 cm) round metal vent. Rigid metal vent isrecommended. For best performance, do not use plastic ormetal foil vent.■ Before making cutouts, make sure there is proper clearancewithin the wall or floor for the exhaust vent.■ Do not cut a joist or stud unless absolutely necessary. If ajoist or stud must be cut, then a supporting frame must beconstructed.■ The size of the vent should be uniform.■ The vent system must have a damper. If roof or wall cap has adamper, do not use damper supplied with the range hood.A. 24" (61.0 cm) on 20" (50.8 cm) single cartridge models30" (76.2 cm) on 30" (76.2 cm) double cartridge models43" (109.2 cm) on 43" (109.2 cm) triple cartridge modelsB. Combustible area above countertop (shown by dashed box above)C. 30" (76.2 cm) minimum clearance between top of cooktop platformand bottom of uncovered wood or metal cabinet (24" [61 cm]minimum clearance if bottom of wood or metal cabinet is coveredby not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered withnot less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainlesssteel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)D. 13" (33 cm) recommended upper cabinet depthE. 2¹⁄₈" (5.4 cm) min.F. 20⁹⁄₁₆" (58.2 cm)G. 18" (45.7 cm) minimum clearance from upper cabinet to countertopwithin minimum horizontal clearances to cooktopH. Junction box or outlet; 12" (30.5 cm) minimum from bottom ofcountertopI. Junction box or outlet; 10" (25.4 cm) from right-hand side ofcabinetJ. 18¹¹⁄₁₆" (47.5 cm) on 20" (50.8 cm) single cartridge models30⁷⁄₁₆" (77.3 cm) on 30" (76.2 cm) double cartridge models41³¹⁄₃₂" (106.6 cm) on 43" (109.2 cm) triple cartridge modelsK. Side clearance - See *NOTE.L. 2" (5.1 cm) minimum clearance between back wall and countertopcutoutDAEIJKGHLCFBA. 18¹¹⁄₁₆" ± ¹⁄₁₆" (47.5 cm ± 0.2 cm) on 20" (50.8 cm) single cartridgemodels30⁷⁄₁₆" ± ¹⁄₁₆" (77.3 cm ± 0.2 cm) on 30" (76.2 cm) double cartridgemodels41³¹⁄₃₂" ± ¹⁄₁₆" (106.6 cm ± 0.2 cm) on 43" (109.2 cm) triplecartridge modelsB. 20⁹⁄₁₆" ± ¹⁄₁₆" (52.2 cm ± 0.2 cm) maximum on all modelsC. 6⁵⁄₁₆" (16.0 cm) on 20" (50.8 cm) single cartridge models17¾" (45.1 cm) on 30" (76.2 cm) double cartridge models17¾" (45.1 cm) on 43" (109.2 cm) triple cartridge modelsD. 14⁷⁄₁₆" (36.7 cm) on all modelsE. 2¹⁄₈" (5.4 cm) minimum space to front edge of cooktopF. Minimum cabinet width:21" (53.3 cm) on 20" (50.8 cm) single cartridge models33" (83.8 cm) on 30" (76.2 cm) double cartridge models43" (109.2 cm) on 43" (109.2 cm) triple cartridge modelsG. Floor exhaust optionH. 6¹⁄₈" (15.6 cm) for 6" vent systemI. 6⁵⁄₁₆" (16.0 cm) on 20" (50.8 cm) single cartridge models17¾" (45.1 cm) on 30" (76.2 cm) double cartridge models17¾" (45.1 cm) on 43" (109.2 cm) triple cartridge modelsJ. 8" (20.3 cm) from center of the vent hole in the cabinet to the topsurface of the countertop, on all modelsK. Wall exhaust optionABCDEGHIJKF