11Fully Integrated Installation - Side ViewAirflow Venting RequirementsFully integrated installations require a minimum of 6" (15.24 cm) ofopen space above the refrigerator. This space must not beblocked in any way, including soffits.Option 1 - Open to CeilingOption 2 - False Front (cabinet face only)Custom Overlay PanelsCustom overlay panels allow you to blend the exterior of yourrefrigerator into the overall kitchen décor and to use customhandles for additional design flexibility.In some cases, your cabinet manufacturer may choose to workwith one panel routed for the different dimensions. Follow thesepanel dimension and placement instructions to be sure that thecustom overlay panels will fit properly.IMPORTANT:■ For 36" (91.4 cm) models, the refrigerator door overlay panelcannot exceed 60 lbs (27.2 kg) and the freezer drawer overlaypanel cannot exceed 25 lbs (11.3 kg).■ For 42" (106.7 cm) models, the refrigerator door overlay panelcannot exceed 40 lbs (18.1 kg) and the freezer drawer overlaypanel cannot exceed 30 lbs (13.6 kg).■ The weight of the top grille overlay panel cannot exceed 7 lbs(3.2 kg) for both models.■ The required thickness for all panels is ³⁄₄" (1.91 cm).■ This installation does not require filler or backer panels.A. False front (optional)B. AirflowC. Full height grilleD. Door panelABCD6" (15.24 cm)min.6" (15.24 cm)min.