Oven Control Testing Procedures! WARNINGTo avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unlesstesting requires power.16025924 4 February 2005©2005 Maytag ServicesControl Component Test Procedure ResultsEOC II End-of-TimerReminder beepsPressSetup Options and the applicable timerpad (Timer 1 orTimer 2) simultaneously.Selects the number of beeps emittedwhen a timed bake cycle ends.EOC II Control Lock PressSetup Options and theControl Lock pad(also the1 pad) simultaneously.PressAutoset to select option (enableor disable). The timer, clock and ovenlight are operational.EOC II Twelve Hour off/Sabbath modePressSetup Options and the12 Hour Off pad(also the2 pad) simultaneously.Disables the normal 12-hour shutoff,allowing the oven to operate indefinitely.EOC II Sound Level(Beeper Volume)PressSetup Options and theSound Level pad(also the3 pad) simultaneously.PressAutoset to select setting (I lowestthrough IIIIIIII 8 highest).EOC II 24-Hour Clock PressSetup Options and the12/24 Hour Clockpad (also the4 pad) simultaneously.PressAutoset to select option (12-hourtime or 24-hour time).EOC II Scroll Speed PressSetup Options and theScroll Speed pad(also the5 pad) simultaneously.PressAutoset to set speed of displayedmessages (slow, medium, fast).EOC II End-of-Cook-TimeSignalPressSetup Options andCook Time Beepspads (also the6 pad) simultaneously.PressAutoset to set the number ofbeeps emitted at the end of a "clock-controlled" cook cycle.EOC II Temperature Display PressSetup Options and theTemp C/F pad(also the7 pad) simultaneously.PressAutoset to select option(°F or °C).EOC II Language Display PressSetup Options and theLanguage pad(also the8 pad) simultaneously.PressAutoset to select option(English, French or Spanish).EOC II Factory Default PressSetup Options and theDefault pad (alsothe9 pad) simultaneously.PressAutoset to reset clock to factorysettings.EOC II Clock Display PressSetup Options and theDisplay On/Off pad(also theClock pad) simultaneously.PressAutoset to select clock display(on or off).EOC II Test Access Press and holdCancel andBroil pads for 3seconds at power up or within 5 minutes of powerup mode. See "Quick Test Mode."Allows access to each function fortesting purposes.Control Panel Assembly Closed circuitry resistance(defined as continuity):1350 – 2250 Ω for Cancel pads 1 & 201275 – 2125 Ω for Cancel pads 2 & 19320 – 2200 Ω for all other padsOpen circuitry resistance:Greater than 10 MΩPin 20Pin 1Pad1234567890CancelClockQuick PreheatBakeBroilKeep WarmConvect WarmConvect RoastCook TimeStop TimeCleanProofingDryingMeat ProbeVent FanAuto SetTimer 1Timer 2Oven LightTrace7 & 814 & 1510 & 146 & 76 & 85 & 64 & 54 & 63 & 43 & 61 & 2or1 & 19or2 & 20or19 & 2013 & 1416 & 1815 & 1616 & 1712 & 136 & 103 & 1810 & 1814 & 1815 & 188 & 109 & 106 & 1811 & 1217 & 1812 & 1410 & 1210 & 11MeasurementContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuity