14PRODUCT DATA SHEETSInterior Water Filtration SystemModel UKF8001AXX-750 Capacity 750 Gallons (2839 Liters)This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. Theconcentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to thepermissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to71.6°F (20°C to 22°C).■ It is essential that operational, maintenance, and filterreplacement requirements be carried out for the product toperform as advertised.■ The disposable water filter should be replaced at least every6 months.■ The filter monitor system measures the amount of water thatpasses through the filter and alerts you to replace the filter.When 90% of the filter’s rated life is used, the yellow (Order)light comes on. When 100% of the filter’s rated life is used, thered (Replace) light comes on, and it is recommended that youreplace the filter. For models without filter status lights,replace the filter every 6 months. Use replacement filtermodel UKF8001AXX-750. 2008 suggested retail price of$44.99 U.S.A./$49.95 Canada. Prices are subject to changewithout notice.■ The product is for cold water use only.■ Do not use with water that is microbiologically unsafe or ofunknown quality without adequate disinfection before or afterthe system. Systems certified for cyst reduction may be usedon disinfected waters that may contain filterable cysts.■ Refer to the “Water Filtration System” section for theManufacturer’s name and telephone number.■ Refer to the “Warranty” section for the Manufacturer’s limitedwarranty.Application Guidelines/Water Supply ParametersSystem tested and certified by NSF International against NSF/ANSIStandard 42 for the reduction of Chlorine Taste and Odor, ParticulateClass I*; and against NSF/ANSI Standard 53 for the reduction ofLead, Mercury, Atrazine, Benzene, p-Dichlorobenzene, Carbofuran,Toxaphene, Cysts, Turbidity, Asbestos and Lindane.Substance ReductionAesthetic EffectsNSF ReductionRequirementsAverageInfluentInfluent ChallengeConcentrationMaximumEffluentAverageEffluentMinimum%ReductionAverage%ReductionChlorine Taste/OdorParticulate Class I* 50% reduction85% reduction 1.88 mg/L5,700,000 #/mL 2.0 mg/L ± 10%At least 10,000particles/mL0.06 mg/L69,000 #/mL ** 0.05 mg/L30,583 #/mL 96.8498.94 >97.2699.52ContaminantReduction NSF ReductionRequirements AverageInfluent Influent ChallengeConcentration MaximumEffluent AverageEffluent Minimum%Reduction Average%ReductionLead: @ pH 6.5Lead: @ pH 8.50.010 mg/L0.010 mg/L0.153 mg/L †0.150 mg/L †0.15 mg/L ± 10%0.15 mg/L ± 10%< 0.001mg/L< 0.001mg/L< 0.001mg/L< 0.001mg/L>99.29%>99.29%>99.35%>99.33%Mercury: @ pH 6.5Mercury: @ pH 8.50.002 mg/L0.002 mg/L0.006 mg/L0.006 mg/L0.006 mg/L ± 10%0.006 mg/L ± 10%0.0005 mg/L0.0015 mg/L0.0003 mg/L0.0008 mg/L90.9175.9395.7086.22Benzene 0.005 mg/L 0.014 mg/L 0.015 mg/L ± 10% 0.0011 mg/L 0.0006 mg/L 92.14% 95.71%p-Dichlorobenzene 0.075 mg/L 0.208 mg/L 0.225 mg/L ± 10% < 0.0005 mg/L < 0.0005 mg/L 99.74% 99.76%Carbofuran 0.04 mg/L 0.081 mg/L 0.08 mg/L ± 10% < 0.001mg/L < 0.001mg/L 98.46% 98.74%Toxaphene 0.003 mg/L 0.015 mg/L 0.015 ± 10% < 0.001mg/L < 0.001mg/L 91.67% 92.97%Atrazine 0.003 mg/L 0.009mg/L 0.009 mg/L ± 10% < 0.002 mg/L < 0.002 mg/L 75.31% 76.99%Asbestos 99% 155 MF/L 10 7 to 10 8 fibers/L †† < 1 MF/L < 1 MF/L >99.99% >99.99%Live Cysts‡Turbidity>99.95%0.5 NTU166,500 #/L10.7 NTU50,000/L min.11 ± 1 NTU< 1 #/L ‡0.49 NTU< 1 #/L ‡0.31 NTU>99.9995.2>99.9997.09Lindane 0.0002 mg/L 0.002 mg/L 0.002 ± 10% < 0.0001mg/L 0.000 mg/L 96.50% 98.72%Water SupplyWater PressureWater TemperatureService Flow RateCity or Well35 - 120 psi (241 - 827 kPa)33° - 100°F (1° - 38°C)0.78 gpm (2.9 L/min.) @ 60 psi***†††‡Class I particle size: >0.5 to <1 umTest requirement is at least 100,000 particles/mL of AC Fine Test Dust.These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.Fibers greater than 10 um in lengthBased on the use of Cryptosporidium parvum oocysts® NSF is a registered trademark of NSF International.