10After the above operation, the burner will produce astable, steady blue flame of minimum size. The settingshould be checked by turning knob from high to lowseveral times without extinguishing the flame.The above operation will automatically provide the properflame size at medium setting.After Conversion Steps A, B and C have been completed,check the appearance of each burner flame at the Hi andLo settings against figure 14. If the flames appear toolarge or too small, review each step to make sure it wascompleted correctly.FIGURE 14FLAME APPEARANCE AT HI AND LOTo Convert Appliance For UseWith Natural GasElectrical power and gas must be turned offprior to conversion.If this appliance has been converted for use with LP gas,each of the following modifications must be performed toconvert the unit back to natural gas.A. REPLACE ALL ORIFICE SPUDS.1. Perform Steps 1 and 2 on page 8.2. Remove chokes from the left front, center and rightrear orifice holder (see figures 10 and 11). Asrequired a simple paper clip can be used to removethe left front and right rear choke.3. Perform Step 3 on page 8.4. For Step 5: Locate the brass natural gas orificespuds that were originally installed in this appliancebefore its conversion for use with LP gas. Observethe number on each of the spuds and note thecorrect burner location for each spud as shown infigures 15 and 16.FIGURE 15Installation Of Natural Gas Orifice Spuds5 BURNER MODEL (36 WIDE)FIGURE 16