Jenn-Air JGCP430W Product Dimensions
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONSJGCP430WJGCP436WJGCP536WJGCP548WType of GasNatural Gas:This cooktop is design-certified by CSA International foruse with Natural gas or, after proper conversion, for usewith LP gas. This cooktop is factory-set for use with Natural gas. Toconvert to LP gas, see the Gas Conversion instructionsprovided in the package containing literature. The model/serial rating plate located on the left underside of thecooktop burner base has information on the types of gasthat can be used. If the types of gas listed do not includethe type of gas available, check with the local gas supplier.LP Gas conversion:Conversion must be done by a qualified service technician.No attempt shall be made to convert the cooktop from thegas specified on the model/serial rating plate for use with adifferent gas without consulting the serving gas supplier. Toconvert to LP gas, use the LP gas converision kit providedwith the cooktop and see the “Gas Conversions” section.Electrical: A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuitis required. A time-delay fuse or circuit breaker is alsorecommended. It is recommended that a separate circuitserving only this cooktop be provided. Electronic ignition systems operate within wide voltagelimits, but proper grounding and polarity are necessary.Check that the outlet provides 120-volt power and iscorrectly grounded.Because Whirlpool Corporation policy includes a continuous commitment to improveour products, we reserve the right to change materials and specifications without notice.Dimensions are for planning purposes only. For complete details, see InstallationInstructions packed with product. Specifications subject to change without notice.Ref. W1014539503/05/2010LOCATION REQUIREMENTSIMPORTANT: Observe all governing codes and ordinances.Do not obstruct flow of combustion and ventilation air. It is the installer’s responsibility to comply withinstallation clearances specified on the model/serial ratingplate. The model/serial rating plate is located on theunderside of the cooktop burner base. It is recommended that a 600 CFM or larger vent hood beinstalled above the cooktop. It is not recommended that a microwave hoodcombination be mounted above the cooktop. The cooktop should be installed in a location away fromstrong draft areas, such as windows, doors and strongheating vents or fans. All openings in the wall or floor where cooktop is to beinstalled must be sealed. Cabinet opening dimensions that are shown must beused. Given dimensions are minimum clearances. Grounded electrical supply is required. See “ElectricalRequirements” section. Proper gas supply connection must be available. See “GasSupply Requirements” section. The cooktop is designed to hang from the countertop byits side or rear flanges. The gas and electric supply should be located as shown in“Gas and Electric Connection Locations” section so thatthey are accessible without requiring removal of thecooktop. Provide cutout in left rear corner of cutout enclosure asshown to provide clearance for gas inlet, power supplycord, and to allow the rating label to be visible.IMPORTANT: To avoid damage to your cabinets, check withyour builder or cabinet supplier to make sure that thematerials used will not discolor, delaminate or sustain otherdamage.Mobile Home - Additional Installation RequirementsThe installation of this cooktop must conform to theManufactured Home Construction and Safety Standard,Title 24 CFR, Part 3280 (formerly the Federal Standard forMobile Home Construction and Safety, Title 24, HUD Part280). When such standard is not applicable, use theStandard for Manufactured Home Installations, ANSIA225.1/NFPA 501A or local codes.In Canada, the installation of this cooktop must conformwith the current standards CAN/CSA-A240-latest edition, orwith local codes.A. 27¹⁄₈" (68.9 cm)B. 30" (76.2 cm) cooktop:⁷⁄₈" (75.1 cm) actual width36" (91.4 cm) cooktop:⁷⁄₈" (90.4 cm) actual width48" (121.9 cm) cooktop:⁷⁄₈" (120.8 cm) actual widthC. Island trim or optional backguardD. 36" (91.4 cm) long 3 prong grounding-type power supply cordE. Model/serial rating plate (located on theunderside of the cooktop burner base)ABCDE293547Page 1 of 2Commercial Style Gas CooktopSide View of CooktopA. 27¾" (70.5 cm)B. 1¼" (3.2 cm)C. 7⁷⁄₁₆" (18.8 cm)D. Gas inlet is located 1⁷⁄₈" (4.8 cm) from the back ofthe cooktop burner base and 4⁷⁄₈" (12.4 cm) infrom left-hand side of the cooktop burner base.E. 22" (55.9 cm)F. 3⁵⁄₁₆" (8.4 cm)G.⁹⁄₁₆" (1.4 cm)ACFG DEB |
Related manuals for Jenn-Air JGCP430W
Jenn-Air JGD3430W Product Dimensions
Jenn-Air JGD3430W Product Dimensions
Jenn-Air JGC9430BD Product Dimensions
Jenn-Air JED3430WS Product Dimensions
Jenn-Air JIC4430X Product Dimensions
Jenn-Air JED4536W Product Dimensions
Jenn-Air JGD8130ADW Product Dimensions
Jenn-Air JED8130AD Product Dimensions
Jenn-Air CVGX2423B Product Dimensions
Jenn-Air LANAI JED7430AAB Product Dimensions
manualsdatabase
Your AI-powered manual search engine