11GAS CONVERSIONSGas conversions from Natural gas to LP gas or from LP gas toNatural gas must be done by a qualified installer.LP Gas Conversion1. Turn manual shutoff valve to the closed position.2. Unplug range or disconnect power.To Convert Gas Pressure Regulator1. Locate gas pressure regulator at the rear of the range.IMPORTANT: Do not remove the gas pressure regulator.2. Unscrew the hex-shaped regulator cap from the regulatorand remove the regulator pin.3. Flip the regulator pin over and snap pin firmly into place.4. Screw the hex-shaped regulator cap securely back intoplace. Do not overtighten.To Convert Oven Bake BurnersTo Convert Lower Oven Bake Burner:1. Remove oven racks from inside the oven cavity.2. Remove oven door. See “Oven Door” section in the Use andCare Guide for oven door removal instructions.A. To rangeB. Shutoff valve (closed position)C. Gas supply lineWARNINGExplosion HazardUse a new CSA International approved gas supply line.Install a shut-off valve.Securely tighten all gas connections.If connected to LP, have a qualified person make suregas pressure does not exceed 14" (36 cm) watercolumn.Examples of a qualified person include:licensed heating personnel,authorized gas company personnel, andauthorized service personnel.Failure to do so can result in death, explosion, or fire.WARNINGTip Over HazardA child or adult can tip the range and be killed.Connect anti-tip bracket to rear range foot.Reconnect the anti-tip bracket, if the range is moved.Failure to follow these instructions can result in deathor serious burns to children and adults.ABCA. Gas pressure regulatorA. Regulator pinB. Regulator capA. Natural gas positionB. LP gas positionAABAB