computer radio control system8.6 Receiver with the EX Bus output- suitable especially for connection to JETI model devices (such asCentral Box)- EX Bus is present at Ext. receiver connector and the telemetrysensors are then connected to the nearest EX Bus expander (e.g.Central Box)- after the receiver is switched on (with the transmitter turned off )it is possible to connect JETIBOX to the receiver via Ext.connector. After the transmitter is switched on, the serialprotocol on Ext. connector changes to EX Bus and theconfiguration using connected JETIBOX is not possible until thetransmitter is switched off or the Rx mode is changed.FailSafe OutputPeriod SerialLink Rx modeEnabled 17 ms (or Auto) EX Bus Normal8.7 Receiver with the UDI output- suitable for connection of devices with unidirectional UDIinterface (e.g. VBar)- UDI output is present on SAT2 output (if it exists), alternatelySAT1 (if it exists), alternately on the last servo output (then thenumber of servo outputs is decreased by one) depending uponyour selected receiver- the servo impulses are generated on other servo outputs it ispossible to connect telemetry sensors to the Ext. connector asusualFailSafe OutputPeriod SerialLink Rx mode UDI ModeEnabled 17 ms (or Auto) JB,UDI Normal Direct29